Troubleshooting

25

2014-02-12

550-353M

Transport

Problem

Cause

Solution

Wings Fail
to Unfold

Hydraulic hose disconnected.
Failed hydraulic hose tip.

Transport locks engaged.

Connect hydraulic hose.

Replace tip.

Disengage transport locks.

Wings Fail
To Fold

Hydraulic hose disconnected.
Failed hydraulic hose tip.

Low hydraulic pressure.

Connect hydraulic hose.

Replace tip.

Increase pressure to be>1500psi (10.3x10^6 Pa).

Folds/
Unfolds Too
Slow

Failed hydraulic hose tip.

Replace tip.

Folds/
Unfolds Too
Fast

Cylinder orifice removed.

Replace orifice in cylinder ports.

Lift Circuit
immobilized

Rebound valve locked.

See dealer.

Lift Will Not
Go Down

Transport locks engaged.

Depth stop engaging.

Failed poppet valve in depth stop.

Depth stop failing due to hose routing.

Disengage transport locks.

Readjust depth stop.

Replace poppet valve in depth stop.

Check routing with hydraulic layout, “Pre-Delivery
Manual”.

Machine
Bouncing
During
Transport

Excessive speed.

Slow down (18 m/h)/(30 km/h).

Advertising