Verifying flow rate limits – Great Plains Raven 440 User Manual
Page 13
2
Manual No. 016-0159-822
9
Introduction
Verifying Flow Rate Limits
The flow rate of spray must be within the specified range for the flow meter being used.
Note:
Only Krohne Magmeters sold through Raven Industries should be used with Raven controllers. No
other Krohne Magmeters are supported.
Flow Meter Model
Flow Range
RFM 5
0.1 - 5 GPM [0.2 - 18.9 lit/min]
RFM 15
0.3 - 15 GPM [1.1 - 56.8 lit/min]
RFM 60P
1 - 60 GPM [3.8 - 210 lit/min]
RFM 60S
1 - 60 GPM [3.8 - 210 lit/min]
RFM 100
5 - 100 GPM [18.9 - 380 lit/min]
RFM 200/200 Poly
15 - 200 GPM [56.8 - 760 lit/min]
Magmeter 200
3 - 200 GPM [11.36 - 757 lit/min]
RFM 400
25 - 400 GPM [94.6 - 1515 lit/min]
Krohne 3” Magmeter*
15 - 250 GPM [56.78 - 946.25 lit/min]
Krohne 4” Magmeter*
35 - 1,800 GPM [132.48 - 6813 lit/min]
Krohne 6” Magmeter*
70 - 3,000 GPM [264.95 - 11,355 lit/min]