Chapter 5

38

SCS 440 Serial Interface Installation & Service Manual

Decimal Shift Feature

Important:

When entering data for Rate 1 Cal and Rate 2 Cal, remember that 2 GPA [20 lit/ha] is entered as 2.0 [20.0]
when the decimal is unshifted, but is entered as 2.00 [20.00] when shifted.

Important:

When shifting or unshifting the decimal place, recheck all calibration values to verify they are correct.

The Decimal Shift feature is used to increase the system’s accuracy at low application rates. The following
table illustrates how shifting the decimal point can increase the system’s accuracy.

Shift the Decimal Place

1.

Press the METER CAL button.

2.

Press the SELF TEST button.

3.

Enter the flow meter calibration value stamped on the identification tag.

4.

Press ENTER.

Unshift the Decimal Place

1.

Press the METER CAL button.

2.

Enter the flow meter calibration value stamped on the identification tag.

3.

Press ENTER.

US

Metric

Turf

Unshifted

Shift

Unshifted

Shift

Unshifted

Shift

Rate Display

000.0

00.00

0000

000.0

00.00

00.00

Rate Cal

000.0

00.00

0000

000.0

00.00

00.00

Tank Volume

0000

000.0

0000

000.0

000.0

000.0

Total Area

000.0

000.0

000.0

000.0

0000

0000

Total Volume

0000

000.0

0000

000.0

000.0

000.0

Field Area

000.0

000.0

000.0

000.0

0000

0000

Field Volume

0000

000.0

0000

000.0

000.0

000.0

Vol/Minute

0000

000.0

0000

000.0

000.0

000.0

Area/Hour

000.0

000.0

000.0

000.0

0000

0000

Rate +/-

000.0

00.00

0000

000.0

00.00

00.00

Low Tank Level

0000

000.0

0000

000.0

000.0

000.0

Low Vol/Min

0000

000.0

0000

000.0

000.0

000.0

Advertising