Console and cabling installation, Caution – Great Plains Raven 440 User Manual

Page 24

Advertising
background image

Chapter 4

20

SCS 440 Serial Interface Installation & Service Manual

Console and Cabling Installation

Note:

The SCS 440 control console may be used with remote boom switches. Connect the boom sense
wires to the switched side of the remote section switches. The boom switches on the SCS 440
must toggled to the OFF position and the master switch ON.

1.

Mount the SCS 440 console to a secure area inside the machine’s cab.

Note:

The SCS 440 console should be mounted in the machine’s cab so that the machine operator has
easy access to it.

2.

Connect the female end of the console control cable into the back of the console.

3.

If using the Raven radar speed sensor:

Connect the red wire on the radar power cable to the orange cable wire on the console control cable.

Connect the white wire on the radar power cable to the white wire on the console control cable.

4.

Turn the POWER ON/OFF switch on the boom switch to OFF.

5.

Connect the speed sensor cable to the back of the console.

6.

Connect the male end of the console cable to the main female connector on the flow control cable.

7.

Secure the speed sensor cable and console control cable with zip ties.

CAUTION

Always connect the power cable as the last
step in the installation process and verify that
the power leads are connected with the correct
polarity. Reversing power leads can cause
severe damage to the equipment.

Advertising