Meter exchange and adjustments, Meter removal – Great Plains YP1625 Operator Manual User Manual
Page 67
Advertising

Great Plains Manufacturing, Inc.
Adjustments
63
03/12/2012
401-226M-A
Meter Exchange and Adjustments
Meter Removal
1.
Clean out meter. See “Meter Clean-Out” on
page 80.
Refer to Figure 90
2.
Slide the retaining ring up on the seed hose, and
remove the seed hose.
FigureSpacer:
Refer to Figure 91
3.
Release the lower latch.
FigureSpacer:
Refer to Figure 92
4.
Release the upper latch and swing the meter mount
away from the meter.
FigureSpacer:
Figure 90
Seed Hose Retaining Ring
22883
FigureSpacer:
Figure 91
Lower Meter Latch
22911
FigureSpacer:
Figure 92
Upper Meter Latch
22911