Small Seeds Rate

Seeding rate from the optional Small Seeds Attachment
is controlled entirely by a seed rate handle on the small
seeds box. No sprocket changes are required, and small
seeds rate is unaffected by settings for main seed box.

Refer to Figure 8

To set Small Seeds rate, loosen the wing nut

at the

handle, and adjust the lever

position. Tighten nut.

Set the initial rate based on the chart in the Seed Rate
Manual.

Small Seeds Rate Calibration

Differences will exist between the tested seed, and field
conditions used to generate the Small Seeds Rate
Charts, and your seed and conditions. To accurately
achieve your target population, Great Plains
recommends calibrating.

Perform the calibration with opener frames lowered (if
the openers are raised, the clutch disengages). Leave
the tractor hitched for movement control.

32. Estimate the sample sizes.

Take your planned population (in our example,

alfalfa at 10 pounds per acre

and divide it by the row count of the drill:

21 in our example.

The expected sample size is 0.48 lbs per row, or

1.43 pounds for 3 sample rows.

33. To perform this calibration, you need a scale that is

accurate near the aggregate sample size, and three
(3) light-weight containers, each capable of holding a
row’s sample.

34. Disengage the lock-out hub (see Operator Manual),

to permit independent rotation of the main jackshaft.

Refer to Figure 9

35. Remove the calibration crank from its storage stob

on the left top side of the main toolbar. Store the
retaining pin on the stob.

Refer to Figure 10

36. Place the hex socket of the crank on the left end of

the main jackshaft.

37. Pull the small seed hoses off the top of three opener

seed tubes, at the top of the openers. Place the
hoses into each sample container.