Row unit setup and adjustment – Great Plains PT1230 Predelivery Manual User Manual

Page 13

Advertising
background image

10

PT1230 Folding Pull-Type Planter 401-072M

10/14/08

Great Plains Mfg., Inc.

Row Unit Setup and Adjustment

The meter clutch and meter-input shaft must be aligned.
Misalignment will cause meter malfunction and excessive
meter-housing wear. Periodically check vertical and hori-
zontal alignment of meter clutch and meter-input shaft.

Refer to Figure 2-4.

1.

Latch hopper onto hopper support.

2.

Check that roll pin (1) in end of the meter-input shaft is
centered. When centered, equal amounts of the roll
pin will protrude from both sides of the shaft.

3.

Rotate meter-input shaft so that roll pin is vertical.

4.

Rotate the drive coupler (2) on meter clutch so that the
slots are vertical.

5.

Release meter clutch to engage meter-input shaft.

6.

If shafts are aligned vertically, the drive coupler will en-
gage with meter-input shaft freely and the roll pin will
extend equally on each side of the drive coupler. Dis-
engage the clutch and repeat steps, checking for hor-
izontal alignment.

17891

Figure 2-4

Vertical Alignment

7.

If drive coupler does not freely engage meter-input
shaft vertically or horizontally, loosen 5/16-inch nuts
(3) shown in Figure 2-4. Engage meter clutch. Align
meter clutch with meter-input shaft.

8.

Tighten 5/16-inch nuts to torque values listed on
Torque Values Chart, “Appendix,” page 11.

Advertising