Finger pickup corn meter, Troubleshooting – Great Plains 8030P G1021 Operator Manual User Manual

Page 25

Advertising
background image

-

23

5/15/06

Great Plains Mfg., Inc.

Section 5 Troubleshooting

60303P and 80303P Three-Point Planter 401-008M

Section 5

Troubleshooting

Finger Pickup Corn Meter

Problem

Possible Cause

Solution

One row not planting seed.

Drive clutch release not engaged.

Engaged clutch release mechanism.

Foreign material in hopper.

Clean hopper and finger carrier mechanism.

Seed hopper empty.

Fill seed hopper.

Row unit drive chain off of sprocket or broken.

Repair or replace drive chain.

Drive release does not engage prop-
erly.

Drive release shaft isn’t aligned properly with
meter drive shaft.

Align drive mechanism. See “Meter Drive
Adjustment”.

Unit is skipping.

Foreign material or obstruction in meter.

Clean out and inspect.

Finger holder improperly adjusted.

Adjust to proper setting. (22 to 25 inch pounds
torque)

Broken fingers.

Replace fingers and/or springs as required.

Planting too slowly.

Increase planting speed to within recommended
range.

Planting too many doubles.

Planting too fast.

Stay within recommended range.

Lose finger holder.

Adjust to specifications (22 to 24 inch pounds
torque)

Worn brush in carrier plate.

Inspect and replace if necessary.

Over planting.

Worn carrier plate.

Inspect and replace if necessary.

Under planting.

Belt installed backwards.

Remove and install correctly.

Weak springs.

Replace.

Spring not properly installed.

Remove finger holder and correct.

Seed belt catching or dragging.

Replace belt.

Brush dislodging seed.

Replace brush.

Irregular or incorrect seed spacing.

Driving too fast.

Check chart for correct speed.

Wrong tire pressure.

Inflate tires to correct air pressure.

Drive wheels slipping.

Reduce down pressure on row unit down force
springs.

Wrong sprockets.

Check planting rate charts for correct sprocket
combinations.

Seed spacing not as indicated in
charts.

Wrong tire pressure.

Inflate tires to correct air pressure.

Inconsistent seed size.

Do field check and adjust sprockets accordingly.

Wrong sprockets.

Check chart for correct sprocket combination.

Charts are approximate.

Slight variations due to wear may produce seed
spacing variations.

Scattering of seeds.

Planting too fast.

Reduce planting speed.

Seed tube improperly installed.

Check seed tube installation.

Seed tube worn or damaged.

Replace seed tube.

Seed tubes and/or openers plugging.

Allowing planter to roll backward when lowering.

Lower planter only when tractor is moving forward.

Inconsistent seed depth.

Rough seed bed.

Adjust down pressure springs

Partially plugged seed tube.

Inspect and clean.

Seed tube improperly installed.

Install properly.

Advertising
This manual is related to the following products: