Install sensor mount, Install sensor, Cut cover clearance holes – Great Plains PD8070 User Manual

Page 4

Advertising
background image

Great Plains Mfg., Inc.

4

Update Kit

402-231M

02/02/2007

Install Sensor Mount

Refer to Figure 8

15. Select one new:

402-426D

HALL EFFECT SENSOR MNT- PRE 07

and two each new:

802-005C HHCS 1/4-20X1 GR5
803-006C NUT HEX 1/4-20 PLT
804-006C WASHER LOCK SPRING 1/4 PLT

16. Install the mount outside the shield

.

Install Sensor

Refer to Figure 9

17. Select one new:

833-451C

DJ HALL EFFECT SENSOR W/NUTS

18. Remove one plastic nut

from the sensor, and

install it on the sensor mount. Temporarily adjust
the exposed length of sensor so that the end of the
sensor is just inside the shield

.

Cut Cover Clearance Holes

Refer to Figure 10

19. Position the cover

against the shield

and

mark areas where the lip of the cover must be cut
away.

20. Test fit the cover

and file any sharp edges.

Figure 8

Install Mount

26005

13

17

19

18

51

13

17

18

19

51

Figure 9

Install Sensor

26006

21

51

1

21

1

51

Figure 10

Mark for Clearance

26000

51

62

62

51

62

Advertising