Bleeding Hydraulics

Bleeding Lift Hydraulics

Normally the lift hydraulics are bled at the factory before
shipping, and bleeding should not be required other than
to raise fully and hold lever on for one minute or until all
cylinders extend fully.

If it is necessary to further bleed lift system, see “Lift
Cylinder Bleeding
” on page 90 belo
w.

Bleeding Fold Cylinder Hydraulics

Normally the fold hydraulics are bled at the factory before
shipping, and bleeding should not be required other than
to fold fully and hold lever on for one minute or until all
cylinders reach the end of their stroke.

Erratic gage wheel behavior, such as wandering back
and forth in the field, or failing to rotate fully into place
while folding, are signs that the fold cylinders need to be
bled.

If it is necessary to further bleed fold system, see “Fold
Cylinder Bleeding
” on page 91.

Lift Cylinder Bleeding

Refer to Figure 119
1.

Unfold and lower planter.

2.

Un-pin rod ends of all lift cylinders. Position cylinders
so that rod ends may extend without striking
machine parts.

3.

Loosen the JIC fittings

at the base end of each

master lift cylinder.

4.

Extend the circuit until fluid appears at the loosened
fittings. Set circuit to Neutral and secure fittings.

5.

Loosen the JIC fittings

at the base end of each

slave lift cylinder.

6.

Extend the circuit until fluid appears at the loosened
fittings. Set circuit to Neutral and secure fittings.

7.

Re-pin rod ends.

Figure 119

Lift Bleed

25227

1

2

1

2

Machine Damage Risk:
Do not fold or unfold without first raising planter completely.

Machine Damage Risk:
Bleed lines only at:

JIC (Joint Industry Conference, 37

°

flare) or

NPT (National Pipe Thread, tapered thread) fittings.

Never bleed at:

ORB (O-Ring Boss) or
QD (Quick Disconnect) fittings.

1