Install orifice plates, Row shut-off, Install orifice plates row shut-off – Great Plains NTA2007 Material Rate User Manual

Page 34

Advertising
background image

32

Great Plains Manufacturing, Inc.

Contents

Appendix

VRG Air Drills

167-085B

Contents

Appendix

2012-01-03

Install Orifice Plates

Refer to Figure 14
7.

Insert the plate inside the gasket

supplied with the

nozzle

. Insert the gasketed plate with the legend

side facing out the nozzle outlet (typically up).

In general, the orifice

needs to be small enough to

create enough pressure in the manifold to operate the
check valves

in the boom clamps, but not so much that

the system dumps product at the boom relief valve.

The recommend operating pressure is: 15 to 40 psi

Using an orifice size too large can result in unequal flow
at rows, intermittent flow, and flow stoppage at rows
where pressure falls below the 8 psi required to open the
clamp check valve. Using a size too small can cause
excess back-pressure resulting in material dumping at
the boom relief valve.

Use the same size at all active rows.

Row Shut-Off

Refer to Figure 14
Unused drop lines may be shut off by replacing the
nozzle

with a Great Plains 832-042C cap

. Twin row

boom systems separately include caps for half the rows.

When installing a cap:

• It is not necessary to remove the gasketed orifice plate

from inside the clamp. The cap includes its own gasket
that seals at the end of the clamp port.

• Use a tie wrap or other line to secure the loose nozzle

and drop line tubing to the boom.

• Adjust pump and/or orifice plates for new rate and row

spacing.

Mis-Application or Material Loss Risk:
Do not apply materials after row shut-off or row turn-on
without first reviewing setup. Merely changing the number of
active rows does not change the application rate. If pump and/
or orifice size changes are not also made, pressures could be
too low or too high.

Equipment Damage Risk:
Plant at or below 8.8 mph (14 kph) with the standard high rate
sprockets installed. The pump is rated for 550 rpm maximum,
which is exceeded at and above 8.9 mph (14.2 kph).

Note: Replacement nozzles include gaskets.

Gaskets may also be ordered separately as Great
Plains part number CP18999-EPR.

Agricultural Chemical Hazard:
Wear protective gloves when changing orifice plates and
strainer screens. Consult material manufacturer or supplier
documents for proper handling and steps to take if skin contact
occurs.

Figure 14

Fertilizer Orifice Plate

29984

Orifice

Part

Port

Port

Size

Number

Diameter

Area

20

832-052C

0.020 in

0.20 mm²

28*

832-056C

0.028 in

0.40 mm²

34*

832-053C

0.034 in

0.59 mm²

48*

832-054C

0.048 in

1.17 mm²

59 832-057C

0.059

in

1.76 mm²

80

832-055C

0.080 in

3.24 mm²

98

832-059C

0.098 in

4.87 mm²

29993

* Sizes standard in many fertilizer bundles.
Check your accessories before ordering.

1

5

3

2

4

2

3

1

4

3

5

Advertising