Quick Setup Guide for IntelliAg Model 3PYP 16 Row Single Row

11001-1468C-201209

©2012 DICKEY-john Corporation
Specifi cations subject to change without notice.

STEP 7: Row Monitor Setup

At the Main Work screen, press the Row Monitor button

.

Enter desired values using Table D as reference.
Press the Work Screen button

to return to the Main Work

screen.

1.
2.
3.

TABLE E:

Speed Set

Default Value

or Value to

Enter

Instructions/Defi nitions

Source

Digital Frequency

Select CAN Ground if radar is connected to ISO tractor cab harness. Select

Digital Frequency if radar or hall-effect is connected to WSMT actuator harness.

Gspd Constant

12192

Input based on pulse count produced by the ground speed sensor over 400’

distance. See Operator’s manual for calibration instructions.

Shutoff Speed

0.5 mph

Set desired minimum ground speed allowed before the system shuts off.

Minimum

Override

2.0 mph

Set to operate when actual ground speed falls below the designated value.

Control will operate at this speed until actual ground speed rises above minimum

override speed or actual speed drops below shutoff.

Master Sw

Timeout

10

Set to desired number of seconds system shuts off if the master switch is turned

on and there is no ground speed. Toggle master switch to restart the system and

turn off alarm.

Gspd Fail Alarm

Delay

5

Set to desired number of seconds alarm sounds after the ground speed is zero

and seed fl ow continues. (Monitor only)

Precharge

Ground Speed

0

Set to the desired speed the system will use when a precharge time has been

enabled for a control channel. Refer to Table C1: Planter Control Setup for

Precharge Time. This setting will only display when a Precharge Time has been

entered.

Implement Lift

Enabled

Implement lift switch, when enabled, displays an implement lift indicator on the

Main Work screen indicating implement lift position as up or down. Control chan-

nels can be turned on and off without using the master switch.

TABLE D:

Row Monitor

Setup

Default Value

or Value to

Enter

Instructions/Defi nitions

Material Name

See Instructions

Material Name only appears on the Row Monitor Setup screen when all control

channels are disabled and material is set for Monitor Only. This is only used for

ground drive/nonhydraulic applications to monitor population with high and low

alarms. A material must be confi gured and selected to activate alarms.

High Alarm Delay

5

Desired number of seconds that high population can be above high alarm point

before alarm will sound.

Low Alarm Delay

5

Desired number of seconds that low population can be below low alarm point

before alarm will sound.

Population Adjust

100

Enter a % to allow for seed sensor population inaccuracies to achieve the

desired population display. 100% represents true calculation.

Population Filter

50

Set fi lter value to stabilize the monitored population display. Number can be set

to 0% for no fi ltering and 99% for high level fi ltering.

Row Fail Rate

2/1 (2 seeds

every 1 second)

Set to desired number of seeds per second to trigger seed sensor failure alarm.

3

STEP 8: Speed Set Calibration Setup

At the Main Work screen, press the Speed Set button

.

Enter desired values using Table E as reference.
Press the Work Screen button

when ground speed calibration

confi gurations are complete to return to the Main Work screen.

1.
2.
3.

TABLE F:

Accessory

Setup

Default Value

or Value to

Enter

Instructions/Defi nitions

Hopper Setup

# of Hoppers

1

# of hopper sensors connected to each module (4 sensors maximum). # of hop-

per data items for each listed module and the Hopp #’s value will automatically

populate if Auto Confi g is used to confi gure installed sensors.

Logic Level

Active Lo

Sets the active state to low signifying that an alarm is generated if the sensor’s

output is in a low state. Use this setting if the connected sensor outputs a low

condition when empty similar to the DICKEY-john hopper sensor.

Alarm Delay

5 sec

Controls the delay time between the detection of a high/low hopper alarm condi-

tion and the generation of the resulting alarm. The value is entered in seconds.

Channel

Assigns hopper sensor to channel.

RPM Setup

High Alarm

(fan speed)

4200 rpm

Sets the RPM value at which a high RPM warning error is generated.

Low Alarm

(fan speed)

2900 rpm

Sets the RPM value at which a low RPM warning error is generated.

High Alarm Delay

0 sec

Establishes the delay between the detection of a high RPM alarm condition and

the resulting alarm display. The value is entered in seconds.

Low Alarm Delay

0 sec

Establishes the delay between the detection of a low RPM alarm condition and

the resulting alarm display. The value is entered in seconds.

RPM Constant

3 pulses/rev

Number of pulses per sensor revolution.

RPM Filter

0

Filters the signal out of the RPM sensor.

Disable Control

on Low Alarm

Disabled

Allows for disabling of all control channels if the RPM value of the selected sen-

sor falls below the low alarm level setting.

STEP 9: Accessory Sensor Setup

Hopper Assignment

At the Main Work screen, press the Next Page button

.

Press the Module Confi guration button

to display the Module

Confi guration screen.
At the Module Confi guration screen, press the Hopper Assign button

.

Press Hopper Set button

.

Enter desired values using Table F as reference.

RPM Assignment

At the Module Confi guration screen, press the Accessory Assignment
button

.

Press the RPM Setup button

. NOTE: There must be at least 1

RPM sensor confi gured before the RPM Setup button appears on the
screen.
Enter desired values using Table F as reference.

1.
2.

3.

4.
5.

6.

7.

8.

STEP 10: Clutch Folding Module (CFM) Setup

The CFM is installed in the cab to control row clutches, wing fold, marker
tilt, and marker fold.

At the Main Work screen, press the Clutch CFG button to access the
Clutch Confi guration screen and verify that the correct # of clutches
are confi gured for the system.
The Clutch CFG button

only appears as a top level button

when a planter output module and clutch folding module are installed.

1.

2.

O U T P U T

1 - 4

# O F
R O W S

R O W
# ’s

5 - 1 2

1 3 - 1 6

LEFT

CENTER
RIGHT

4

8

4

# of Clutches 3