TROUBLESHOOTING / 11

TROUBLESHOOTING

Alarms will display on the Virtual Terminal with an audible alarm. The alarm
can be silenced by pressing the Alarm Cancel or ESC button. Detailed
descriptions of the alarm can be viewed by pressing the Alarm Detail
button. Some alarm conditions display instructions to aid in troubleshooting
the situation. Each alarm type has an associated alarm number for
reference.

DOWN PRESSURE UNABLE TO CONTROL

Alarm 265

The system is unable to monitor or control down pressure. Full screen
alarm identifies the module unable to control.

Corrective Action

• Check for sufficient tank pressure.
• Check load cell sensor for damage.
• Check air valve for damage.
• Inspect module and module harness for damage.
• Verify constants entered at the Down Pressure Setup screen are

correct.

Figure 11
Down Pressure Unable to Control Alarm

Contact DICKEY-john Technical Support Group at 1-800-637-3302 for
troubleshooting assistance or questions.