6 / ROW-PRO DOWN PRESSURE SETUP

RESET OFFSET VALUE

Resetting Offset Values clears previous down pressure readings and resets
values to zero.

Reset Offset Values:

1. At the Main Work screen, press the Next Page button.
2. Press the Module Cfg button.
3. At the Module Configuration screen, press the Dpress Set button.
4. At the Down Pressure Setting screen, press the OK button to clear

values.

IMPORTANT: The implement must be lifted and the implement lift

switch in the up state before the OK button appears and
values can be cleared.

Figure 6
Reset Offset Values

NOTE: Verify that side depth wheels

are not stuck in a position to
leave a residual pressure on
the load cell.

When planter is lifted,

OK button appears

to reset values.