Operator’s manual, Reset offset value – Great Plains DICKEY-john Down Pressure Control User Manual
Page 8
OPERATOR’S MANUAL
Row-Pro Down Pressure Control
11001-1572-201008
6 / ROW-PRO DOWN PRESSURE SETUP
RESET OFFSET VALUE
Resetting Offset Values clears previous down pressure readings and resets
values to zero.
Reset Offset Values:
1. At the Main Work screen, press the Next Page button.
2. Press the Module Cfg button.
3. At the Module Configuration screen, press the Dpress Set button.
4. At the Down Pressure Setting screen, press the OK button to clear
values.
IMPORTANT: The implement must be lifted and the implement lift
switch in the up state before the OK button appears and
values can be cleared.
Figure 6
Reset Offset Values
NOTE: Verify that side depth wheels
are not stuck in a position to
leave a residual pressure on
the load cell.
When planter is lifted,
OK button appears
to reset values.
112
106
128
120
115
111