Air release tube, Meter box door seals, Meter flutes – Great Plains YP40F Operator Manual User Manual
Page 47: Seasonal
Advertising

Great Plains Manufacturing, Inc.
Maintenance
43
2013-03-25
403-362M
Air Release Tube
1 tube each wing end fertilizer delivery hose;
2 tubes per planter
Inspect. Clean any build-up on screen. Replace if
damaged. Re-install with opening facing down.
Note: Although depicted in exploded view, the tube is a
weldment and the screen cannot be removed.
Meter Box Door Seals
2 seals per planter
Inspect and replace if leaks are detected or appear
imminent.
Meter Flutes
1 flute shaft per planter,
2 sets of 2 stars (4 stars),
4 sets of 3 stars (12 stars);
16 stars total (each star is two halves)
Inspect from above with hopper empty. Shaft rotation is
required to expose all surfaces. Replace any broken or
visibly worn stars.