Quick setup guide for intelliag model cta – Great Plains CTA4000 Quick Start User Manual

Page 3

Advertising
background image

11001-1459C-201107

©2011 DICKEY-john Corporation
Specifi cations subject to change without notice.

Quick Setup Guide for IntelliAg Model CTA

STEP 6B: Channel Setup (Granular Fertilizer Monitor)

Channel 2 is generally used for granular fertilizer monitor setup.

At the Channel Setup screen, press the Next Channel button

to

setup additional control channels.

Set channel 2 as granular fertilizer monitor.

Enter desired values using Table F as reference.

Continue to set up control channels 3 and 4, if required.

Press the Work Screen Button

when channel confi gurations are

complete to return to the Main Work screen.

Once a Control Channel has been established as Granular Fertilizer Monitor,
any new materials established as granular fertilizer monitor on the Material
Setup screen will automatically be added as optional materials for granular
fertilizer monitor channels on the Control Setup screen.

1.

2.

3.

4.

5.

TABLE F:

Channel Setup

Gran Fert Mon

Default Value/

Value to Enter

Instructions/Defi nitions

Type

Gran Fert Monitor Set desired channel type as Gran Fert Monitor.

Material Name

Fert 5

Displays only materials that have been confi gured for the channel type.

Input Filter

50

Feedback frequency fi lter for the Control Channel. DO NOT CHANGE.

Sensor Constant

360

Sensor Constant establishes the number of pulses for one revolution of

the feedback sensor. If a DICKEY-john application rate sensor is used, the

value should be set to 360.0.

Gear Ratio

1.0

Specifys the actual ratio from the feedback sensor to the seed meter shaft

RPM. Number of revolutions the feedback sensor turns in relation to one

revolution the seed meter turns.

Channel Width

480

Manual entry of the channel width for rows assigned to a specifi c channel.

Width calculation can be determined by # of seeder rows assigned to the

channel multipled by the row spacing.

Step 6C only applies to those applications with a variable rate
kit option installed. Proceed to Step 7 if variable rate is not ap-
plicable.

STEP 6C: Channel Setup (Granular Seed & Fertilizer Control)

Press the Channel Setup button

.

Select an available channel and set to either granular seed control or

granular fertilizer control.

Enter desired values using Table G as reference.

To set up additional control channels, press the Next Channel button

.

Press the Work Screen button

when channel confi gurations are

complete to return to the main menu.

1.

2.

3.

4.

5.

TABLE G:

Channel Setup

Gran Seed &

Fert Setup

Default Value/

Value to Enter

Instructions/Defi nitions

Type

Gran Seed

Control/Gran Fert

Control

Set desired Channel Type as either Gran Seed Control or Gran Fertilizer

Control

Material Name

Seed 1/Fert 1

Displays only materials that have been confi gured for the channel type.

Control Mode

Auto

Calculates application rates based on ground speed and channel width

under normal operating conditions.

Drive Type

Zero Max

A Zero Max gear box controlled by a linear actuator for those applications

with an installed variable rate kit option.

Drive Frequency

40

The Hz frequency for the linear actuator specifi ed by the valve manufac-

turer.

Input Filter

50

Feedback frequency fi lter for the control channel. DO NOT CHANGE.

Sensor Constant

360

Sensor constant establishes the number of pulses for one revolution of

the feedback sensor. If a DICKEY-john application rate sensor is used, the

value should be set to 360.0.

Gear Ratio

1.0

Specifys the actual ratio from the feedback sensor to the seed meter shaft

RPM. Number of revolutions the feedback sensor turns in relation to one

revolution the seed meter turns.

Grd Spd/Trans In

Ratio

45

Ratio between distance traveled to one revolution of the input to the Zero

Max transmission. Ratio determines the input sprocket speed from the

known ground speed.

Meter Gear Range

High/Low

Determined by the position of the interchangeable gears. High range used

for larger seeds and higher seeding rates. Low range used for smaller

seeds and lower seeding rates. Refer to Great Plain’s operator’s manual for

recommended high/low setting.

# of Seed Rows

50 row

Entry of a specifi c number of seed rows to the control channel. Row

assignment is given a priority based on the channel and will be assigned

sequentially thereafter. Channel 1 is always assigned to the fi rst set of rows.

Channel 2 next set of rows, and so on.

65 row

80 row

Channel Width

480

Manual entry of the implement width for rows assigned to a specifi c chan-

nel. Width calculation can be determined by # of seeder rows assigned to

the channel multipled by the row spacing.

Flush Enable

Disabled

Not applicable to ground drive systems.

Precharge Time

+ 0.0

Not applicable to ground drive systems.

Delay Time

- 0.0

Not applicable to ground drive systems.

3