Quick Setup Guide for IntelliAg Model CTA

11001-1459C-201107

©2011 DICKEY-john Corporation
Specifi cations subject to change without notice.

STEP 8: Accessory Sensor Setup

Hopper Setup

Press the Module Confi guration button

.

Press the Hopper Assign button

.

Verify # of hoppers is correct or enter # of hoppers assigned.
Press the Hopper Set button

.

Enter desired values using Table I as reference.

RPM Sensor Setup

Press the RPM Module button

.

Enter # of RPM sensors, if required.
Press the RPM Setup button

.

Enter desired values using Table I as reference.

Pressure Sensor Setup

At the Module Confi guration screen, press the PSI Module button

.

Verify # of pressure sensors or enter the # of pressure sensors as-
signed.
Press the Pressure button

.

Enter desired values using Table I as reference.

For additional information regarding hopper level, RPM, and pressure
sensor setup, reference the Operator’s manual.

1.
2.
3.
4.
5.

6.
7.
8.
9.

9.

10.

11.

12.

TABLE I:

Accessory

Setup

Default Value or

Value to Enter

Instructions/Defi nitions

# of Hoppers

2

# of hopper sensors connected to each module. # of hopper data items

for each listed module and the Hopp #’s value will automatically populate if

Auto Confi g is used to confi gure installed sensors.

Hopper Logic

Level

Active Lo

Sets the active state to low signifying that an alarm is generated if the

sensor’s output is in a low state. Use this setting if the connected sensor

outputs a low condition when empty similar to the DICKEY-john hopper

sensor.

Hopper Alarm

Delay

5 sec

Controls the delay time between the detection of a high/low hopper alarm

condition and the generation of the resulting alarm. The value is entered

in seconds.

Channel

(Hopper #1)

1

Assigns hopper sensor 1 to channel 1.

Channel

(Hopper #2)

2

Assigns hopper sensor 2 to channel 2.

# of RPMs

1

Number of RPM sensors connected to each module to monitor a shaft/fan.

High Alarm

4100 RPM

Sets the RPM value at which a high RPM warning error is generated.

Low Alarm

2500 RPM

Sets the RPM value at which a low RPM warning error is generated.

High Alarm Delay

5 sec

Establishes the delay between the detection of a high RPM alarm condition

and the resulting alarm display (entered in seconds).

Low Alarm Delay

5 sec

Establishes the delay between the detection of a low RPM alarm condition

and the resulting alarm display (entered in seconds).

RPM Constant

3 pul

Number of pulses per sensor revolution.

RPM Filter

50%

Filters the signal out of the RPM sensor.

Disable Control on

Low Alarm

Disabled

Allows for disabling of all control channels if the RPM value of the selected

sensor falls below the low alarm level setting.

# of Pressure

Sensors

2

Number of pressure sensors connected to each module to monitor pres-

sure.

High Alarm

20 oz/in

2

Sets the pressure value at which a high pressure warning error is gener-

ated (oz/in

2

).

Low Alarm

4 oz/in

2

Sets the pressure value at which a low pressure warning error is generated

(oz/in

2

).

High Alarm Delay

5 sec

Establishes the delay between the detection of a high pressure alarm

condition and the resulting alarm display (entered in seconds).

Low Alarm Delay

5 sec

Establishes the delay between the detection of a low pressure alarm condi-

tion and the resulting alarm display (entered in seconds).

Pressure Filter

50

Filters the signal out of the pressure sensor.

Press in

highlighted

box to open

Channel Selection

Accessory Selection

Summary Screen

4

STEP 7: Ground Speed Calibration Setup

Press the Speed Set button

.

Enter desired values using Table H as reference.

Press the Work Screen button

when Ground Speed Calibration

confi gurations are complete to return to the Main Work screen.

1.

2.

3.

TABLE H:

Ground Speed

Setup

Default Value or

Value to Enter

Instructions/Defi nitions

Source

Digital Frequency

Select CAN Ground if radar is connected to ISO tractor cab harness. Select

Digital Frequency if radar or hall-effect is connected to WSMT actuator

harness.

Gspd Constant

3440 Pul/400 ft

Input based on pulse count produced by the ground speed sensor over 400’

distance. See Operator’s manual for calibration instructions.

Shutoff Speed

0.01 mph

0.02 kph

Indicates the minium ground speed allowed before the system shuts off all

control channels.

Min Override

0.0 mph

0.0 kph

Minimum Override takes over when actual ground speed is below the

designated value. The control operates at this speed until actual ground

speed rises above the minimum override speed or the actual speed drops

below the shutoff speed.

Master Switch

Timeout

5 sec

Determines the length of time before the system disables the operate func-

tion after ground speed is 0 if the master switch remains in the ON position.

Ground Speed

Failure Alarm

Delay

5 sec

Set to desired number of seconds alarm sounds after the ground speed is

zero and seed fl ow continues. (monitor only)

Implement Lift

Enabled

Implement lift switch must be in the down position to operate.

STEP 9: Summary Screen

The Summary screen provides an overview of setup constants for active
control channels.

At the Main Work screen, press the Next Page button

.

Press the Summary button
To view specifi c control channel confi gurations, press the respective
control channel box 1-4.
Press inside a yellow highlighted box to open a specifi c screen for
editing.
Press the Work Screen button

to return to the Main Work screen.

1.
2.
3.

4.

5.