Installation Instructions

3

03/01/2007

407-189M

Remove Old Elbow

Refer to Figure 3

8.

Remove and save two:

HYPRO NUT

9.

Remove the old elbow:

HYPRO FLANGE

The flange and O-ring are not re-used.

10. If the existing O-ring

does not come off with the

old elbow, remove it from the face of the pump. The
new elbow uses a different size O-ring.

11. Rinse any spilled fluids from the pump, pump fit-

tings, implement frame and row units beneath.

12. Clean the face of the discharge port

on the

pump.

Assemble New Fittings

Refer to Figure 4

Assemble the new fittings prior to mounting on pump, so
that you have maximum flexibility in matching the origi-
nal elbow orientation.

13. Select one each new:

407-173D STAINLESS FITTING
816-045C O-RING 15/16 I.D. X 1-1/8 O.D.
830-041C AD 1/2MNPT POLYPROP
830-048C EL 1/2MNPT X 1/2FNPT POLYP

14. Apply pipe thread sealant to threads and assemble

fittings

,

and

as shown. Do not over-

tighten.

15. Insert O-ring

in face of flange

.

Do not use any sealant on O-ring.