STEP 7A: Material Confi guration Setup
(Split Air Regulation)
It is recommended that when setting a control channel for split air, the
material name be created as “Air” to eliminate confusion between the
actual material and the control used.
At the Main Menu screen, press the Control Setup button
.
Select the Material 16 button.
Enter desired values from Table D.
Press the Work Screen button
to return to the Main Work screen.
1.
2.
3.
4.
TABLE D:
Material
Setup
Default
Value/ Value
to Enter
Split Air Regulation
Instructions/Defi nitions
Type
Split Air Reg
Desired type of application control channel being used for a specifi c material.
CREATE MATERIAL NAME AS “AIR”.
Units
In H20
Oz in2
Automatically changes with the type of material application selected. Changes
units for target application.
Preset Method
Disabled
User-defi ned target rates can be confi gured and when enabled can be adjusted
from the Main Work screen using the Increment/Decrement buttons.
Target Rate
2.00
Establishes the desired rate of application in inches of H20.
Max Rate
5.00
Maximum application rate in inches of H20.
Min Rate
1.00
Minimum application rate in inches of H20.
Inc/Dec %
5%
Percentage of change of the entered target rate applied each time the Incre-
ment/Decrement button is pressed on the Main Work screen.
TABLE E:
Planter Control
Setup
Default
Value/Value
to Enter
Split Air Regulation
Instructions/Defi nitions
Type
Split Air Reg
Confi gure control channel 2 as Split Air Regulation.
Control Mode
Auto
Control channel feedback based on air pressure sensor.
Drive Type
Air Reg 2
Automatically selects Air Reg 2 as drive type.
Input Filter
79
Amount of fi ltering applied to the control channel feedback frequency.
Pressure Drop
0
Difference in pressure sensor mounting location to the seed disk in inches of
H20.
Pressure Slope
447.2269
The change in pressure sensor voltage to a frequency readable by the IntelliAg
system and measured in inches of H20. Should only be adjusted by qualifi ed
personnel.
Pressure Offset
800
Takes a zero point reading that provides a frequency when the fan is off. Press
the Zero Pressure button to calculate frequency.
Planter Selection
3PYP
Select planter selection of 3PYP automatically adjust to the appropriate calibra-
tion settings.
Sensitivity Adjust
0
Increases or decreases the calibration parameters in the ranges of -10 to +10.
Increasing response time makes the system response quicker.
STEP 7B: Planter Control Channel Setup
(Split Air Regulation)
NOTE: Split Air Regulation must be confi gured as Control Channel 2
only.
At the Control Setup screen, press the Channel Setup button
.
Select Channel 2 and select Split Air Regulation as the Type.
Enter desired values from Table E.
Press the Work Screen button
to return to the Main Work
screen.
1.
2.
3.
4.
STEP 8: Row Monitor Setup
At the Main Work screen, press the Row Monitor button
.
Enter desired values using Table F as reference.
Press the Work Screen button
to return to the Main Work screen.
1.
2.
3.
TABLE F:
Row Monitor
Setup
Default
Value/Value
to Enter
Instructions/Defi nitions
Material Name
See
Instructions
Material Name only appears on the Row Monitor Setup screen when all control
channels are disabled and material is set for Monitor Only. This is only used for
ground drive/nonhydraulic applications to monitor population with high and low
alarms. A material must be confi gured and selected to activate alarms.
High Alarm Delay
5
Desired number of seconds that high population can be above high alarm point
before alarm will sound.
Low Alarm Delay
5
Desired number of seconds that low population can be below low alarm point
before alarm will sound.
Population Adjust
100
Enter a % to allow for seed sensor population inaccuracies to achieve the
desired population display. 100% represents true calculation.
Population Filter
50
Set fi lter value to stabilize the monitored population display. Number can be set
to 0% for no fi ltering and 99% for high level fi ltering.
Row Fail Rate
2/1 (2 seeds
every 1
second)
Set to desired number of seeds per second to trigger seed sensor failure alarm.
3