Great Plains 3PYPA-1238 12 Row 38-Inch Quick Start User Manual

Page 3

Advertising
background image

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

11001-1531A-201209

©2012 DICKEY-john Corporation

Specifi cations subject to change without notice.

STEP 7A: Material Confi guration Setup
(Split Air Regulation)

It is recommended that when setting a control channel for split air, the
material name be created as “Air” to eliminate confusion between the
actual material and the control used.

At the Main Menu screen, press the Control Setup button

.

Select the Material 16 button.

Enter desired values from Table D.

Press the Work Screen button

to return to the Main Work screen.

1.
2.

3.

4.

TABLE D:

Material

Setup

Default

Value/ Value

to Enter

Split Air Regulation

Instructions/Defi nitions

Type

Split Air Reg

Desired type of application control channel being used for a specifi c material.

CREATE MATERIAL NAME AS “AIR”.

Units

In H20

Oz in2

Automatically changes with the type of material application selected. Changes

units for target application.

Preset Method

Disabled

User-defi ned target rates can be confi gured and when enabled can be adjusted

from the Main Work screen using the Increment/Decrement buttons.

Target Rate

2.00

Establishes the desired rate of application in inches of H20.

Max Rate

5.00

Maximum application rate in inches of H20.

Min Rate

1.00

Minimum application rate in inches of H20.

Inc/Dec %

5%

Percentage of change of the entered target rate applied each time the Incre-

ment/Decrement button is pressed on the Main Work screen.

TABLE E:

Planter Control

Setup

Default

Value/Value

to Enter

Split Air Regulation

Instructions/Defi nitions

Type

Split Air Reg

Confi gure control channel 2 as Split Air Regulation.

Control Mode

Auto

Control channel feedback based on air pressure sensor.

Drive Type

Air Reg 2

Automatically selects Air Reg 2 as drive type.

Input Filter

79

Amount of fi ltering applied to the control channel feedback frequency.

Pressure Drop

0

Difference in pressure sensor mounting location to the seed disk in inches of

H20.

Pressure Slope

447.2269

The change in pressure sensor voltage to a frequency readable by the IntelliAg

system and measured in inches of H20. Should only be adjusted by qualifi ed

personnel.

Pressure Offset

800

Takes a zero point reading that provides a frequency when the fan is off. Press

the Zero Pressure button to calculate frequency.

Planter Selection

3PYP

Select planter selection of 3PYP automatically adjust to the appropriate calibra-

tion settings.

Sensitivity Adjust

0

Increases or decreases the calibration parameters in the ranges of -10 to +10.

Increasing response time makes the system response quicker.

STEP 7B: Planter Control Channel Setup
(Split Air Regulation)

NOTE: Split Air Regulation must be confi gured as Control Channel 2
only.

At the Control Setup screen, press the Channel Setup button

.

Select Channel 2 and select Split Air Regulation as the Type.

Enter desired values from Table E.

Press the Work Screen button

to return to the Main Work

screen.

1.

2.

3.

4.

STEP 8: Row Monitor Setup

At the Main Work screen, press the Row Monitor button

.

Enter desired values using Table F as reference.
Press the Work Screen button

to return to the Main Work screen.

1.
2.
3.

TABLE F:

Row Monitor

Setup

Default

Value/Value

to Enter

Instructions/Defi nitions

Material Name

See

Instructions

Material Name only appears on the Row Monitor Setup screen when all control

channels are disabled and material is set for Monitor Only. This is only used for

ground drive/nonhydraulic applications to monitor population with high and low

alarms. A material must be confi gured and selected to activate alarms.

High Alarm Delay

5

Desired number of seconds that high population can be above high alarm point

before alarm will sound.

Low Alarm Delay

5

Desired number of seconds that low population can be below low alarm point

before alarm will sound.

Population Adjust

100

Enter a % to allow for seed sensor population inaccuracies to achieve the

desired population display. 100% represents true calculation.

Population Filter

50

Set fi lter value to stabilize the monitored population display. Number can be set

to 0% for no fi ltering and 99% for high level fi ltering.

Row Fail Rate

2/1 (2 seeds

every 1

second)

Set to desired number of seeds per second to trigger seed sensor failure alarm.

3

Advertising
This manual is related to the following products: