Great Plains 3PYPA-1238 12 Row 38-Inch Quick Start User Manual

Page 4

Advertising
background image

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

11001-1531A-201209

©2012 DICKEY-john Corporation

Specifi cations subject to change without notice.

4

STEP 11: Clutch Folding Module (CFM) Setup

The CFM is installed in the cab to control row clutches, wing fold, marker tilt, and marker
fold.

At the Main Work screen, press the Clutch CFG button to access the Clutch Confi gu-
ration screen and verify that the correct # of clutches are confi gured for the system.
The Clutch CFG button

only appears as a top level button when a planter

output module and clutch folding module are installed.

1.

2.

O U T P U T

1 - 3

# O F
R O W S

R O W
# ’ s

4 - 9

1 0 - 1 2

LEFT

CENTER
RIGHT

3

6

3

# of Clutches 3

TABLE H:

Accessory

Setup

Default Value

or Value to

Enter

Instructions/Defi nitions

Hopper Setup

# of Hoppers

1

# of hopper sensors connected to each module (4 sensors

maximum). # of hopper data items for each listed module and

the Hopp #’s value will automatically populate if Auto Confi g is

used to confi gure installed sensors.

Logic Level

Active Lo

Sets the active state to low signifying that an alarm is gener-

ated if the sensor’s output is in a low state. Use this setting

if the connected sensor outputs a low condition when empty

similar to the DICKEY-john hopper sensor.

Alarm Delay

5 sec

Controls the delay time between the detection of a high/low

hopper alarm condition and the generation of the resulting

alarm. The value is entered in seconds.

Channel

Assigns hopper sensor to channel.

RPM Setup

High Alarm

(fan speed)

3000 rpm

Sets the RPM value at which a high RPM warning error is

generated.

Low Alarm

(fan speed)

1800 rpm

Sets the RPM value at which a low RPM warning error is

generated.

High Alarm Delay

10 sec

Establishes the delay between the detection of a high RPM

alarm condition and the resulting alarm display. The value is

entered in seconds.

Low Alarm Delay

10 sec

Establishes the delay between the detection of a low RPM

alarm condition and the resulting alarm display. The value is

entered in seconds.

RPM Constant

3 pulses/rev

Number of pulses per sensor revolution.

RPM Filter

0

Filters the signal out of the RPM sensor.

Disable Control

on Low Alarm

Disabled

Allows for disabling of all control channels if the RPM value of

the selected sensor falls below the low alarm level setting.

STEP 10: Accessory Sensor Setup

Hopper Assignment

At the Main Work screen, press the Next Page button

.

Press the Module Confi guration button

to display the Module Confi guration

screen.
At the Module Confi guration screen, press the Hopper Assign button

.

Press Hopper Set button

.

Enter desired values using Table H as reference.

RPM Assignment

At the Module Confi guration screen, press the Accessory Assignment button

.

Press the RPM Setup button

. NOTE: There must be at least 1 RPM sensor

confi gured before the RPM Setup button appears on the screen.
Enter desired values using Table H as reference.

1.
2.

3.
4.
5.

6.
7.

8.

TABLE G:

Speed Set

Default Value

or Value to

Enter

Instructions/Defi nitions

Source

Digital Frequency

Select CAN Ground if radar is connected to ISO tractor cab

harness. Select Digital Frequency if radar or hall-effect is

connected to WSMT actuator harness.

Gspd Constant

12192

Input based on pulse count produced by the ground speed

sensor over 400’ distance. See Operator’s manual for

calibration instructions.

Shutoff Speed

0.5 mph

Set desired minimum ground speed allowed before the

system shuts off.

Minimum

Override

2.0 mph

Set to operate when actual ground speed falls below the des-

ignated value. Control will operate at this speed until actual

ground speed rises above minimum override speed or actual

speed drops below shutoff.

Master Sw

Timeout

10

Set to desired number of seconds system shuts off if the

master switch is turned on and there is no ground speed.

Toggle master switch to restart the system and turn off alarm.

Gspd Fail Alarm

Delay

5

Set to desired number of seconds alarm sounds after the

ground speed is zero and seed fl ow continues. (Monitor only)

Precharge

Ground Speed

0

Set to the desired speed the system will use when a pre-

charge time has been enabled for a control channel. Refer

to Table C1: Planter Control Setup for Precharge Time. This

setting will only display when a Precharge Time has been

entered.

Implement Lift

Enabled

Implement lift switch, when enabled, displays an implement

lift indicator on the Main Work screen indicating implement lift

position as up or down. Control channels can be turned on

and off without using the master switch.

STEP 9: Speed Set Calibration Setup

At the Main Work screen, press the Speed Set button

.

Enter desired values using Table G as reference.
Press the Work Screen button

when ground speed calibration confi gurations

are complete to return to the Main Work screen.

1.
2.
3.

Advertising
This manual is related to the following products: