STEP 1: Pre-Programming Preparation:

Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings.
If errors are detected (e.g., failed sensors, incorrect confi guration) an alarm and code displays. Alarms are silenced by pressing the Alarm Cancel button

. Refer to Operator’s

manual for troubleshooting assistance.

The system has three user levels. The system loads in User Level 1 (operator level) at every power cycle. Access to User Level 2 and 3 screens to setup constants (system confi gura-

tion) requires a password.

1.
2.

3.

The Quick Setup Guide assumes the Virtual Terminal, Master Switch, Working Set Master Module, Working Set

Member Module, and all sensors have been connected and properly installed. Reference Operator’s manual

for installation instructions. NOTE: The master switch is only required for hydraulic control systems.

Reference the manual for instructions to assign a master switch as an auxiliary input.

STEP 3: Auto Confi guration (Identifi es sensors connected to each module)

Auto confi g is performed at the factory, but may need to be done in the fi eld as changes are
made to the system or if options are added to the base planter.

Verify Auto Confi g results are correct. Check that the correct number of rows are assigned to the
correct module and number of hopper sensors are assigned accurately.

To Run Auto Confi g:

Press the Next Page button

until the Module Confi guration button appears.

Press the Module Confi guration button

.

Press the AUTO CONFIG button

.

Hour glass will indicate system is being confi gured detecting the presence of seed or hopper
sensors connected to each module and will be automatically assigned to the appropriate
module.
When Auto Confi g completes, press the Row Assign button

to display the Row Assign-

ment screen to verify correct Row # is assigned to the correct module based on serial number.
Enter # of rows assigned to each module.

1.

1.

2.

3.
4.

5.

6.

STEP 4: Row Status/Row Width Setup

At the Row Assignment screen, press the Row I/O button

.

Begin entering desired values using Table A as reference.
Press the Work Screen button

when Row Status/Row Width confi gurations are com-

plete to return to the Main Work screen.

1.
2.
3.

TABLE A:

Row Status/Row

Width Setup

Default Value

or Value to

Enter

Instructions/Defi nitions

Row Width

20”

Enter row width distance in inches to calculate seed

rate correctly. NOTE: Using 15” planter in 30” mode

should change On/Off Pattern to Every 2nd Row Off.

Auto Update Width

Enabled

When enabled, implement width will automatically

calculate. If disabled, manually enter implement

width.

On/Off Pattern

Every Row On

On/Off Pattern indicates specifi c row patterns to

be on or off. Select pre-defi ned planter All Row On

pattern. For other pre-defi ned planter patterns or in-

dividual row settings, reference Operator’s manual.

Pop/Block Pattern

Every Row

Population

Determines which sensors are used to calculate

population and those used only for blockage detec-

tion. Select pre-defi ned Every Row Population. For

other pre-defi ned patterns, reference Operator’s

manual.

1

S E R I A L
N U M B E R

1

M O D U L E
T Y P E

M O D U L E
A D D R .

WSMB-POM
WSMB-POM

2

WSMB-18R

3

10001

10001
10002

WSMT-GY
WSMB-Rows
WSMB-POM
WSMB-CFM

10001
10002
10003
10001

4
5
6
7

# O F

R O W S

MODULE

ADDR.

TYPE

R O W

# ’s

1 5 - 2 2

1

WSMB-18R

2

WSMT-GY

8

14

1- 14

3

WSMB-Rows

1 4

2 3 - 3 6

Module Configuration Screen

Seed Sensor Configuration Screen

optional

optional

STEP 2: Change User Level to Dealer Level

To change the user level, a 6-digit password is required. Password includes the fi ve-digit se-
rial number found on the label of the Working Set Master or Information screen.

On the IntelliAg Main Work screen, press the Diagnostics button

.

At the Diagnostics screen, press the Information button

.

At the Information screen, record serial number of WSMT.
Press the Password button

.

On the Password screen, enter the 6 digit password as follows: enter the fi rst digit as 2 for User
Level 2. For the next fi ve digits, enter the Working Set Master serial number taken from the
WSMT or Information screen.
Press the OK button

. “Dealer screens on” appears at the bottom of screen confi rming the

password and dealer screens are activated.
Press the Work Screen button to return to the Main Work screen.

1.
2.
3.
4.
5.

6.

7.

STEP 5A: Material Confi guration Setup (Controlled Hydraulic Drive)

15 different materials can be confi gured for use as planter controls. Reference the System Con-
fi guration section in the Operator’s manual for additional information.

At the Main Menu screen, press the Control Setup button

.

Select and press one of the Material buttons (Material 1-15).
Enter desired values from Table B1.
Press the Control Setup button

to return to the Control Setup screen.

Repeat steps 2-4 for additional materials.
Press the Channel Setup button

to proceed to channel setup screen.

1.
2.
3.
4.
5.
6.

TABLE B1:

Material Setup

Default Value/

Value to Enter

Controlled Hydraulic Drive

Instructions/Defi nitions

Matrl Label

Matrl 1

Material Name can be customized to accurately

defi ne the material’s type. Creating a name allows

for quick identifi cation at the Control Setup screen.

Type

Planter Control

Desired type of application control channel being

used for a specifi c material. The Material Type must

correctly match the Control Type to be able to select

Material from the Material Summary screen and

operate properly.

Units

Ks/Ac

S/Sec

Automatically changes with the type of material

application selected. Changes units for target

application.

Preset Method

Enable

Enabled Preset Method allows 10 user-defi ned tar-

get rates to be adjusted from the Main Work screen

using Inc or Dec buttons. A Disabled Preset Method

increases/decreases the target rate based on the %

values set at the Material Setup screen.

Seeds per Rev

See Manual

Set to number of seeds per 1 disc revolution.

Disc Low Limit

(Air Pro)

5

Set to desired min seed disc RPM.

Disc High Limit

(Air Pro)

37

Set to desired max seed disc RPM.

High Pop Alarm

15%

This is the percentage above the target population

of the planter channel if rows are assigned to the

planter channel. If rows are not assigned to a

planter, this is the percentage above average planter

population for all unassigned rows.

Low Pop Alarm

15%

This is the percentage below the target population

of the planter channel if rows are assigned to the

planter channel. If rows are not assigned to a planter

channel, this is the percentage below average

planter population for all unassigned rows.

Product Level

Alarm

Sets the level to trigger an alarm alerting of low

product levels. Entered value is an estimate in

volume.

Row Fail Rate

2/1 (2 seeds

every 1 second)

Set to desired number of seeds per second to trig-

ger seed sensor failure alarm.