6

Wet Pickup:

To protect the HEPA filter, always use the HEPA filter cover
part number 13301.

After Wet Pickup:

Unscrew drain cap from bottom of tank. This drain can be
regulated so that a floor drain can be used conveniently.
The liquid can be regulated from a drip to a full flow.

The suction hose can be put in the drain cap to drain liquid
to an extended location.

Rinse inside of tank thoroughly with clean water
particularly if spills or other substances other than
water have been picked up. Wipe inside of tank dry.
Screw drain cap
back on tightly so it
is ready for use
again.

Automatic Wet
Shut-off:

When the tank is full of liquid, the automatic
shut-off mechanism will shut off air flow. When
this happens, the motor sound will become
noticeably higher in pitch. Turn cleaner off
and empty tank to continue use.

Storage:

Disconnect cleaner from electrical outlet. Empty tank.
Rinse inside of tank thoroughly with clean water
particularly if spills or other liquid substances other than
plain water have been picked up. Wipe inside of tank dry.
If tank is stored with liquid left inside, the moisture may
cause damage to the motor and its internal parts.

Wands and tools as well as hose store right on the tool
tray. Wands store on each of the back legs in the
circular grooves provided.

Lubrication:

The motor is equipped with bearings which contain
sufficient lubrication for the life of the motor.
The addition of lubricant could cause damage.
Do not add lubricant to motor bearings.

If you have a problem:

This appliance was inspected thoroughly and was in good
operating condition when it was shipped from the factory.
If a minor problem occurs, it usually can be solved quite
easily when the cause is found. Therefore, this Trouble
Shooting Guide is provided for your convenience.