Calibration and setup, cont – Cardinal Industries 225 WEIGHT INDICATOR User Manual

Page 59

Advertising
background image

CALIBRATION AND SETUP, CONT.


SETU

With S
SETUP

T

e

(1) scale.
three (3) sc
referenced

wn.

he following describes the Scale Setup for the 225. The standard 225 supports on

With the optional 225-DS Dual Scale card installed, it can support up to

ales. In the setup menus shown and parameters described, Scale 1 is

. Substitute the scale number you are configuring for the number sho

P SCALE

ETUP MENU #1 displayed, press NEXT (Navigation Keys

Down Arrow) to proceed to

MENU #2.

SETUP MENU #2

1. SERIAL

2. DIO
3. PRINT TABS
4. SETUP SCALE 1
5. CALIBRATE 1
Enter Selection: 0

`

NEXT

^

PREV


4. S

With
to S

ETUP SCALE 1

the SETUP MENU #2 displayed, press the 4 key and then the ENTER key to proceed

CALE 1 SETUP MENU #1.

SCALE 1 SETUP MENU #1

1. BASE UNITS=X XX 6. SAMPLES=XXX

2. CNVT UNITS=X XX 7. STABLE=XX
3. Z TRACK=X.X 8. STBL CNT=XXX
4. Z LIMIT=XXX

9. WT INTERVALS=XX

5. PWR UP Z=XXX
Enter Selection: 0

`

NEXT

^

EXIT

1. BASE

NITS)

With S

#1 displayed the current setting for the

BASE UNITS=

param

XX is the description. If

the setting displayed is acceptable, proceed to the next setup parameter.

key and then using the numeric keys, enter the

press the ENTER key to save the new setting and

. Allowable values are 0 through 6.

UNITS=X XX (BASE U

CALE 1 SETUP MENU

eter will be shown. Note that X is the current value and

Otherwise, press the 1 key, the ENTER
value for the base units and then
return to SCALE 1 SETUP MENU #1

8200-M538-O1

y 225 Installation