SPECIFI CATIONS

Power Requirements:

90 to 264 VAC (50/60 Hz) at 0.4A

Enclosure Type:

NEMA 4X/IP66 Stainless Steel

Enclosure Size:

10 7/8"W x 8 3/16"H x 3 1/8"D (276mm W x 208mm H x 79mm D)

Weight:

9.2lbs (Size and Weight DOES NOT include Gimbal)

Operating Environment: Temperature: 14 to 104 ºF (-10 to +40 ºC)

Humidity: 90% non-condensing (maximum)

Display:

240 x 64 (5” x 1.33”) Graphics LCD w/ LED Backlight

Transducer Excitation:

12 VDC

Signal Input Range:

1.0 mV min. to 40 mV max. (with dead load boost)

Scales

1 ea Standard, 3 ea with optional 225-DS Dual Scale Input Board

Number of Load Cells:

14 each, 350 OHM minimum resistance

Load Cell Cable Length: 1500 feet maximum with sense lines.

30 feet maximum without sense lines

Division Value:

1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 and 0.0001 commercial
0 to 99, non-commercial

Sensitivity:

NON-COMMERCIAL
NTEP
CANADA
OIML


0.15 uV/e
0.3uV/e (Class III/IIIL)
0.3uV/e (Class III/IIIHD)
0.7 uV/e (Class III)

Scale Divisions:

NON-COMMERCIAL
NTEP
CANADA
OIML


100 to 240,000
100 to 10,000 (Class III/IIIL)
100 to 10,000 (Class III/IIIHD)
100 to 10,000 (Class III)

Internal Resolution:

1 part in 16,777,216

Tare Capacity:

Six Digits (999,999)

Sample Rate:

1 to 100 samples per second, selectable

Auto Zero Range:

0.5 or 1 through 9 divisions

Weighing Units:

Tons, Pounds, Ounces, Tonnes ”Metric Tons”, Kilograms, Grams,

Keypad:

Membrane type with 60 color-coded keys

Standard I/O:

U

4ea Serial I/O Ports configured as:

3 ea bi-directional RS-232 ports or 3ea 20mA output-only ports
1 ea bi-directional 20mA/IR port
1 ea output only RS-232/20mA port
8 ea Remote Isolated Inputs
16 ea Remote Isolated Outputs

Consult factory for

other requirements

8200-M538-O1