Baumer BMxx, GBxxx-GXxxx - EtherCAT / PoE from version&nbsp,5.0 User Manual

Page 11

Advertising
background image

Baumer_EtherCAT_PoE_5-00_MA_EN.docx

11/30

www.baumer.com

30.09.14

Object 0x1011 RESTORE Application Parameter

Object 0x1011 restores ROM default in device-specific objects (0x6000..0x6FFF) both in RAM and EEPROM.
To prevent any inadvertent restore, the signature „load“ must be written in object 0x1011 Subindex 0.

Signature

MSB

LSB

ISO 8859

character

hex

dez

Object 0x1018 Identity Object

SubIndex

0

Data type

Unsigned 8

Access

ReadOnly

Default

4

EEPROM

No

Significance

Maximum supported subindex

Values

4 = Maximum supported subIndex


SubIndex

1

Data type

Unsigned 32

Access

ReadOnly

Default

Ech

EEPROM

No

Significance

VendorID for Baumer IVO GmbH & Co. KG assigned by CiA

Values

0xEC (in the Internet under www.can-cia.de)


SubIndex

2

Data type

Unsigned 32

Access

ReadOnly

Default

0x0A  GXMMW_H ; 0x0B  GXAMW_H
0x0C  GCMMW_H ; 0x0D  GCAMW_H
0x0E  GBMMW_H, 0x0F  GBAMW_H

EEPROM

No

Significance

Product Code

Values


SubIndex

3

Data type

Unsigned 32

Access

ReadOnly

Default

EEPROM

No

Significance

Revision no.

Values


SubIndex

4

Data type

Unsigned 32

Access

ReadOnly

Default

EEPROM

No

Significance

Serial no.

Values

d

a

o

l

0x64

0x61

0x6F

0x6C

1684107116