Parameterization, 3 parameterization – Baumer BMxx, GBxxx-GXxxx - EtherCAT / PoE from version&nbsp,5.0 User Manual

Page 17

Advertising
background image

Baumer_EtherCAT_PoE_5-00_MA_EN.docx

17/30

www.baumer.com

30.09.14

5.3 Parameterization


Proceed as below for user-specific parameterization of direction of rotation, resolution, total resolution, preset:


Examples: Scaling ON in object 0x6000

Scaling

Rotation

Value 0x6000

OFF

CW

0x0000

OFF

CCW

0x0001

ON

CW

0x0004

ON

CCW

0x0005


Object 0x6000 Operating

parameters

Scaling: ON Bit 2 = 1

Rotation: Bit 0 = 0 CW , 1=CCW


Object 0x6002 Total measuring range

Mutiturn

Object 0x6001 Measuring units per revolution

Saved non-

volatile

Object 0x1010 SAVE

Value :0x65766173

End

Object 0x6003 Preset,

Referencing

J

J

J

N

N

N

CW = clockwise = increasing values with
clockwise shaft rotation

CCW = counterclockwise = increasing values
with counterclockwise shaft rotation

Reference: when looking at flange

Advertising