5.3 Parameterization
Proceed as below for user-specific parameterization of direction of rotation, resolution, total resolution, preset:
Examples: Scaling ON in object 0x6000
Scaling
Rotation
Value 0x6000
OFF
CW
0x0000
OFF
CCW
0x0001
ON
CW
0x0004
ON
CCW
0x0005
Object 0x6000 Operating
parameters
Scaling: ON Bit 2 = 1
Rotation: Bit 0 = 0 CW , 1=CCW
Object 0x6002 Total measuring range
Mutiturn
Object 0x6001 Measuring units per revolution
Saved non-
volatile
Object 0x1010 SAVE
Value :0x65766173
End
Object 0x6003 Preset,
Referencing
J
J
J
N
N
N
CW = clockwise = increasing values with
clockwise shaft rotation
CCW = counterclockwise = increasing values
with counterclockwise shaft rotation
Reference: when looking at flange