Baumer BMxx, GBxxx-GXxxx - EtherCAT / PoE from version&nbsp,5.0 User Manual

Page 15

Advertising
background image

Baumer_EtherCAT_PoE_5-00_MA_EN.docx

15/30

www.baumer.com

30.09.14

Object 0x6003 Preset value

SubIndex

0

Data type

Unsigned 32

Access

ReadWrite

Default

0

EEPROM

Yes

Significance

Optionally programmable position value.
In this operation an offset value is calculated and saved in object 0x6509.

Values

0..actual total measuring range (0x6002) -1
Entries ≠ default values are only effective with enabled scaling function (0x6000).

Object 0x6004 Position value

SubIndex

0

Data type

Unsigned 32

Access

ReadOnly

Default

EEPROM

No

Significance

Value of actual position in steps

Values

0..actual total measuring range (0x6002) -1


Object 0x6030 Speed value

SubIndex

0

Data type

Signed 32

Access

ReadOnly

Default

EEPROM

No

Significance

Current speed value

Values

Unit steps/s or rpm configurable by object 0x6000 Bit 12


Object 0x6031 Speed Parameter

SubIndex

0

Data type

Unsigned 8

Access

ReadOnly

Default

2

EEPROM

No

Significance

Largest supported Subindex

Values

2 = largest supported SubIndex


SubIndex

1

Data type

Unsigned 16

Access

ReadOnly

Default

2

EEPROM

No

Significance

Speed Source

Values

2: Speed is calculated out o raw data position


SubIndex

2

Data type

Unsigned 16

Access

Readwrite

Default

100

EEPROM

Yes

Significance

Integration time in ms, to generate the moving average speed value.
To enhance dynamic capabilities select an inferior value.
To improve smoothing select a larger value.

Values

1..1000