Options and accessories, Electric heaters – Carrier 13 50XP User Manual

Page 5

Advertising
background image

5

50XP

Factory-installed options
Coil options

include Tin-Plated* indoor hairpins, copper/

copper and vinyl-coated construction for refrigerant coils.
Units are shipped standard with copper tube/aluminum fin
construction. See model number nomenclature for coil
options.
*Tin-Plated indoor coils are built with special hairpins
that are designed to resist both general pitting corrosion
and excessive indoor corrosion (Formicary Corrosion).

Field-installed accessories

Economizer with solid-state controls and barometric
relief dampers

includes filter racks and provide outdoor air

during cooling and reduce compressor operation.

Manual outside air damper

includes hood and filter rack

with adjustable damper blade for up to 25% outdoor air.

Electric heaters

provide heat in the unit when required.

Each package has a heater module that slides into the
controls compartment. Heater sizes range from 5 to 20 kW.
The electric heater design allows the use of a single-point

power supply for the entire unit, resulting in lower installed
costs.

Flat roof curbs

in both 8 in. and 14 in. sizes are available

for roof mounted applications.

Square-to-round duct transition kit

enables 024-048 size

units to be fitted to 14 in. round ductwork.

Thermidistat Control

coupled with the system’s variable

speed indoor blower delivers Carrier’s patented
IdealHumidity™ Technology that allows for even greater
humidity control. Along with more precisely controlling
temperature and humidity, the Thermidistat offers full
seven-day programmability allowing you to further
customize your comfort and energy savings.

Thermostats

provide control for the system heating and

cooling functions. Thermostat models are available in both
programmable and non-programmable versions.

Lifting kit,

including 4 metal brackets that are available to

assist in lifting this product onto a roof application.

Crankcase heater

provides anti-floodback protection for

low-load cooling applications.

Low-ambient kit (Motormaster II control)

allows the

use of mechanical cooling down to outdoor temperatures as
low as 0°F.

Solid-state Time Guard II device

provides short-cycling

protection for the compressor. Not required with corporate
electronic thermostats.

Filter rack

features easy installation, serviceability, and

high-filtering performance for vertical or horizontal
applications.

Compressor Hard start kit

assists compressor start-up by

providing additional starting torque on single phase units
and prolongs compressor motor life.

Economizer with Solid-State Controls and Barometric

Relief Dampers

Manual Air Damper (25% open)

Electric Heaters

Filter Rack

Flat Roof Curbs (8-in. and 14-in.)

Square-to-Round Duct Transition Kit

Thermidistat™

Thermostats

Crankcase Heater

Rigging Kit

Low Ambient Kit (Motormaster® II Control)

Solid-State Time Guard® II Device

Lifting Kit

Compressor Hard Start Kit

Options and accessories

ELECTRIC HEATERS

LEGEND

ODS — Order Distribution System
NOTE: Electric heaters are rated at 240 v. Refer to Multiplication Factors table for other voltages.

MINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION

ODS CATALOG

ORDERING NO.

NOMINAL CAPACITY

(kW)

USED WITH SIZES

024

030

036

042

048

060

ELECTRIC HEATERS (208/230 — SINGLE PHASE — 60 Hz)

CPHEATER052A00

5.0

X

X

X

X

X

X

CPHEATER069A00

7.5

X

X

X

X

X

X

CPHEATER065A00

10.0

X

X

X

X

X

X

CPHEATER051A00

15.0

X

X

X

X

X

CPHEATER053A00

20.0

X

X

X

ELECTRIC HEATERS (208/230 — 3 PHASE — 60 Hz)

CPHEATER055A00

5.0

X

X

X

X

X

CPHEATER056A00

10.0

X

X

X

X

X

CPHEATER057A00

15.0

X

X

X

X

CPHEATER059A00

20.0

X

X

X

UNIT

024

030

036

042

048

060

AIRFLOW

750

750

1250

1205

1500

1800