Table 30 – Cabletron Systems Cabletron CyberSWITCH CSX400 User Manual

Page 233

Advertising
background image

EPIM Specifications

CSX400 and CSX400-DC User’s Guide

219

Table 30 Transmitter Power

Parameter

Typical Value

Worst
Case

Worst
Case
Budget

Typical
Budget

50/125

µ

m fiber

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125

µ

m fiber

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140

µ

m fiber

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate

Better than 10

-10

NOTE

The transmitter power levels and receive sensitivity levels listed are Peak Power Levels
after optical overshoot. A Peak Power Meter must be used to correctly compare the
values given above to those measured on any particular port. If Power Levels are being
measured with an Average Power Meter, then 3 dBm must be added to the
measurement to correctly compare those measured values to the values listed
(i.e., -30.5 dBm peak = -33.5 dBm average).