If Bridging,

•

Check that the Bridging Default Destination is set.

•

Check that bridging to/from the remote router is set on.

•

Be sure to reboot if you have made any bridging destination or control changes.

If TCP/IP Routing,

•

Check that TCP/IP Routing is set on and is enabled at the remote end.

•

Check that the IP address of the LAN beyond the remote router is correct, as well as the
associated Subnet Mask.

•

If the remote router WAN IP address and Subnet Mask are required, check that they have been
specified correctly.

•

Check that, if required, the source and remote WAN IP addresses are on the subnetwork.

•

Check that you have seeded the routing table, if RIP is not allowed to flow on the WAN link.

•

Be sure to reboot if you have made any IP address, control or protocol option changes.