Fan trays, Management interface modules, Fan trays management interface modules – Cisco SFS 7008 User Manual

Page 17

Advertising
background image

17

•

The power supplies are 1U, 48V, 1200W

•

The supplies provide regulated +48V DC to all other modules in the system.

•

Each power supply has self contained fans for cooling.

Fan Trays

Refer to

“Installing a Fan Module” on page 41

for installation instructions.

The fan trays are redundant, hot-swappable cooling units.
•

Only one fan tray, in either of the two slots, is required to cool the system. However, a blanking
panel is required for any unused bay.

•

The replacement of any one fan tray does not disrupt the operation of the device in any way, and
can be successfully completed without having to remove the device from a rack, or disconnect any
cables.

•

The fan modules use DC Voltage regulators to control fan speed and contain a hardware fan control
circuit, which controls and monitors the fan speed.

•

The fan module will default to full speed after a power-on or reset condition.

•

If one the fans fails, the redundant fan will go to full speed (if one is available).

CAUTION: The fan modules do not have guards. Do not remove a fan module completely from the
bay until the blades have stopped moving (approximately 15 seconds).

Management Interface Modules

See

Figure 1-2 on page 14

for a diagram of the chassis.

Refer to

“Installing a Management Interface Module” on page 50

for installation instructions.

The Topspin 270 supports redundant, hot-swappable Management Interface modules, each of which is
paired to one of the Fabric Controller Core modules.
The Management Interface modules provide the following functions:
•

RS-232 serial console port

•

10/100 Ethernet management port

•

System real time clock (RTC)

•

Intra-system Ethernet switch, which provides a system configuration management data-path to all
fabric modules.

•

Provide mirrors of the LED indicators from the front side of the chassis for the power supply, fans,
and over-all system status. (refer to

“Management Interface Module LEDs” on page 71

).

•

Rack Alarm Connection (refer to

“Rack Alarm” on page 19

).

Figure 1-5: Management Interface Module

Rack Alarm

Ethernet
Port

Serial
Port

Redundant
LEDs

(not supported)