Table 5-7, Table 5-8, Location – Cisco SFS 7008 User Manual

Page 72: Interpreting the management interface leds

Advertising
background image

72

Location

The Management Interface modules are located at the top of back the chassis. Refer to

Figure 5-5

to

view the chassis diagram.

Figure 5-6: Management Interface Module LEDs

Interpreting the Management Interface LEDs

System Status LEDs

Management Interface Status LEDs

Table 5-7: Interpreting the Management Interface Module System Status LEDs (see

Figure

5-6

)

Color

State

Indication

Green and Yellow

off

No module power, or LED failure.

Green

solid on

System running with no errors detected.

Green

off

No power to the Management Interface module, LED failure,
or yellow LED is ON.

Yellow

solid on

At least one module failure in the system. Operator attention
required.
The “!” label indicates a failure.

Yellow

blinking

Identify. Assists in identifying a particular Field Replaceable
Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
Run the identity test on Power Supply 1:
config mode -> diag card 15 ->
test led ->
-> start - start flashing
-> stop - stop flashing

Table 5-8: Interpreting the Management Interface Module Status LEDs (see

Figure 5-6

)

Color

State

Indication

Green over Yellow

off

No module power, or LED failure.

Green

solid on

The Management Interface module is running with no errors
detected.