Upgrading individual node cards, Upgrading a node card with the cli – Cisco SFS 7008 User Manual

Page 59

Advertising
background image

59

5. Activate the image. After downloading the image file to the chassis controller, it must be installed

to become active. The install command installs the specified image file into the system.
a.

In the privileged-execute mode, enter install image:image-file-name.img

Example

6. Specify the new boot image to be used.

a.

Find the name of your new system image by entering the dir image command. Copy the name
of the new image.

b. Enter boot-config primary-image-source, then paste the copied image file name.

Example

7. Reset the individual Controller card without rebooting the whole chassis.

Example

Upgrading Individual Node Cards

Upgrading a Node Card with the CLI

For the commands needed to upgrade a node card using the CLI, refer to the CLI Reference Guide.

Topspin-270# install image:Topspin-270-TopspinOS-2.2.0-build531.img
*****************operation completed successfully

Topspin-270# configure
Topspin-270(config)# boot-config primary-image-source TopspinOS-2.2.0/build531
Topspin-270(config)# exit

Topspin-270(config)# card 12
Topspin-270(config-card-12)# action reset