Lim status leds, Infiniband port leds, Lim status leds infiniband port leds – Cisco SFS 7008 User Manual

Page 75: Infiniband, Location, Interpreting the lim status leds

Advertising
background image

75

LIM Status LEDs

Location

The LIM Status LED is located at the far left of each LIM card (if you are facing the back of the
chassis). Refer to

Figure 5-5

for a complete diagram of the back panel of the chassis.

Figure 5-8: LIM Status Indicator LEDs

Interpreting the LIM Status LEDs

InfiniBand Port LEDs

The InfiniBand LED represents the logical link and the logical link activity.

Table 5-13: Interpreting the Chassis ID Status LEDs (see

Figure 5-7

)

Color

State

Indication

Green/Yellow

off

No module power, or LED failure.

Green

solid on

Chassis ID module is running with no errors detected.

Green

off

No power to the Chassis ID module, LED failure, or yellow
LED is On.

Yellow

solid on

Failure of the Chassis ID module. Operator attention required.
The “!” label indicates a failure.

Yellow

blinking

Identify a Chassis ID module. Assists in identifying a
particular Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.

LIM Status Indicator

Table 5-14: Interpreting the LIM Status LED

Color

State

Indication

Green and
Yellow

off

No module power, or LED failure.

Green

solid on

Line Interface module is running with no errors
detected.

Green

off

No power to the Line Interface module, LED
failure, or yellow LED is On.

Yellow

solid on

Failure of the Line Interface module. Operator
attention required.
The “!” label indicates a failure.

Advertising