Dell PowerVault MD3200 User Manual

Page 16

Advertising
background image

14

Getting Started With Your System

RAID controller module

Six single-color LEDs:

• One battery fault

• One cache active

• One controller fault

• One controller power

• One system identification

• One management Ethernet activity

Six two-color LEDs:

• Four SAS IN link or fault

• One SAS OUT link or fault

• One management Ethernet link speed

Switch

System identification button

Located on the front control panel. This button is
used to locate a system within a rack.

Enclosure mode switch

Located on the front of the system. This switch is
not applicable to the PowerVault MD3200 series
storage array.

Password reset switch

Located on the back-panel of the RAID controller
module. This switch is used to reset the storage array
password.

Power Supplies

AC power supply (per power supply)

Wattage

600 W

Voltage

100–240 VAC (8.6 A–4.3 A)

Heat dissipation

100 W

Maximum inrush current

Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach a maximum of 55 A per power supply for
10 ms or less.

LED Indicators (continued)

Advertising
This manual is related to the following products: