5 - menu tree structure – Carrier PRO-DIALOG 30GK User Manual

Page 14

Advertising
background image

14

MENU

Legend

**

Displayed if the alarm exists

-

Not in use

ITEM

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

ST

A

TUS

Def

ault displa

y

Activ

e

modes

Chiller occupied/

unoccupied

Min

utes left bef

ore

star

ting

Cooling/heating

selection

Heat reclaim

selection

Unit capacity in %

Capacity circuit A

in %

Capacity circuit B

in %

Present demand

limit in %

Present lag limit in

%

Setpoint in local

control

Setpoint occupied/

unoccupied mode

Activ

e

setpoint

Control point

Controlled w

ater

temperature

Condensing point

Heat reclaim

indicator

, circuit A

Heat reclaim

indicator

, circuit B

TEMP

E

v

aporator w

ater

enter

ing temp

.

E

v

aporator w

ater

lea

ving temp

.

Condenser w

ater

enter

ing temper

ature

Condenser w

ater

lea

ving temperature

Heat reclaim w

ater

enter

ing temper

ature

Heat reclaim w

ater

lea

ving temperature

Satur

ated discharge

temper

ature

, circuit A

Satur

ated suction

temper

ature

, circuit A

Suction temper

ature,

compressor A1

Superheat, circuit A

Satur

ated discharge

temper

ature

, circuit B

Satur

ated suction

temper

ature

, circuit B

Suction temper

ature

compressor B1

Superheat, circuit B

Outdoor temper

ature

W

ater loop temp

.,

master/sla

v

e

assemb

ly

-

-

-

PRESSURES

Discharge pressure

,

circuit A

Suction pressure, circuit

A

Oil diff

erential pressure

,

compressor A1

Discharge pressure

,

circuit B

Suction pressure

,

circuit B

Oil diff

erential pressure

,

compressor B1

Oil diff

erential pressure

,

compressor A2

Oil diff

erential pressure

,

compressor A3

Oil diff

erential pressure

,

compressor A4

Oil diff

erential pressure

,

compressor B2

Oil diff

erential pressure

,

compressor B3

Oil diff

erential pressure

,

compressor B4

Heat reclaim pressure,

circuit A

Heat reclaim pressure,

circuit B

-

-

-

-

-

SETPOINTS

Cooling setpoint 1

Cooling setpoint 2

Heating setpoint

Condensing setpoint

Heat reclaim setpoint

Demand limit setpoint

in %

Cooling mode r

amp

Heating mode ramp

Cooling - threshold f

o

r

z

ero reset

Cooling - threshold f

o

r

max. reset

Cooling - max. reset

v

alue

Heating - threshold f

o

r

z

ero reset

Heating - threshold f

o

r

max. reset

Heating - max. reset

v

alue

-

-

-

-

-

INPUTS

Contact 1: remote on/off

Contact 2: remote

setpoint

Contact 3: remote

heating/cooling

Contact 4: remote heat

reclaim oper

ation

Demand limit selection

W

ater flo

w & customer

inter

loc

k control

E

v

aporator pump f

ault

detection

W

ater flo

w control,

condenser

Control bo

x ther

mostat

Exter

nal 0-10

V d.c.

signal

-

-

-

-

-

-

-

-

-

OUTPUTS

Compressor status,

circuit A

Compressor status,

circuit B

Capacity reduction

status, circuits A & B

F

an contactor status,

circuit A

F

an contactor status,

circuit B

Alar

m circuit status

,

circuits A & B

EXV position, circuit A

EXV position, circuit B

V

a

riab

le speed f

an,

circuit A or cond. water

v

alv

e position in %

V

a

riab

le speed f

an,

circuit B or cond. water

v

alv

e position in %

W

ater pump 1 status

W

ater pump 2 status

Condenser pump status

E

v

a

p

. heater & heat

reclaim cond. status

Cond. water v

alv

e posi-

tion, heat reclaim mode

Solenoid status

, heat

reclaim function

User test interf

ace

-

-

CONFIG

SUB-MENU:

User Conf

igur

ation [USEr]

SUB-MENU:

Ser

vice Conf

igur

ation

[SEr

viCE]

SUB-MENU:

F

actor

y

Conf

igur

ation

[F

A

CtorY]

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

ALARMS

Number of activ

e alar

m

s

/

resets

Activ

e alar

m

code 1**

Activ

e alar

m

code 2**

Activ

e alar

m

code 3**

Activ

e alar

m

code 4**

Activ

e alar

m

code 5**

-

-

-

-

-

-

-

-

-

-

-

-

-

4.5 - Menu tree structure

ALARMS HIST

Historic alar

m code 1

Historic alar

m code 2

Historic alar

m code 3

Historic alar

m code 4

Historic alar

m code 5

Historic alar

m code 6

Historic alar

m code 7

Historic alar

m code 8

Historic alar

m code 9

Historic alar

m code 10

-

-

-

-

-

-

-

-

-

R

UNTIMES

SUB-MENU:

Runtimes 1

SUB-MENU:

Runtimes 1

SUB-MENU:

Maintenance

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

NOTE: The items in brackets show what is displayed on the

user interface.

Advertising