Information Update

System Message Update

Table 1-1 lists new system messages for the PowerEdge 2900 III system
and the probable cause and corrective action if the message appears.

CAUTION:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. See your Product
Information Guide for complete information about safety precautions,
working inside the computer, and protecting against electrostatic discharge

Table 1-1.

System Messages

Message

Causes

Corrective Actions

Alert! Node

Interleaving

disabled! Memory

configuration does

not support Node

Interleaving.

The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a failed
DIMM) so that node
interleaving cannot be
supported.

The system

runs but with reduced
functionality.

Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages
for additional information
for possible causes.
For memory configuration
information, see
“General Memory Module
Installation Guidelines”
in the Hardware Owner’s
Manual. If the problem
persists, see
“Troubleshooting System
Memory” in the Hardware
Owner’s Manual.

!!*** Error: Remote

Access Controller

initialization

failure *** RAC

virtual USB devices

may not be

available...

Remote Access Controller
initialization failure

Ensure that the Remote
Access Controller is
properly installed. See
“Installing a RAC Card”
in the Hardware Owner’s
Manual.

Invalid PCIe

card found in the

Internal_Storage

slot!

The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.

Remove the PCIe expansion
card and install the internal
SAS controller in the
dedicated slot.