Dell PowerEdge 2900 User Manual

Page 15

Advertising
background image

Information Update

15

Table 1-2.

LCD Status Messages

Code

Text

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character string that
can be defined by the user
in the System Setup
program.

The SYSTEM NAME
displays under the
following conditions:

• The system

is powered on.

• The power is off

and active errors
are displayed.

This message is for
information only.

You can change the
system ID and name
in the System Setup
program. See “Using the
System Setup Program”
in the Hardware Owner’s
Manual.

E1000

FAILSAFE,

Call Support

Check the system event
log for critical failure
events.

See “Getting Help” in
the Hardware Owner’s
Manual.

E1118

CPU Temp

Interface

The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.

Turn off power to the
system and restart the
system. If the problem
persists, see “Getting
Help” in the Hardware
Owner’s Manual.

E1211

ROMB Batt

RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.

Reseat the RAID battery
connector. See the “RAID
Battery” and see
“Troubleshooting System
Cooling Problems” in
the Hardware Owner’s
Manual.

E1625

PS AC Current

Power source is out
of acceptable range.

Check the AC power
source.

Advertising