Dell PowerEdge 2900 User Manual

Page 17

Advertising
background image

Information Update

17

E171F

PCIE Fatal Err

B## D## F##

The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCIe
configuration space at bus
##, device ##, function
##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see “Troubleshooting
Expansion Cards” in
the

Hardware Owner’s

Manual.

PCIE Fatal Err

Slot #

The system BIOS has
reported a PCIe fatal error
on a component that
resides in the specified
slot.

Reinstall the expansion-
card riser. See “Expansion
Card Risers” in the
Hardware Owner’s
Manual.
If the problem persists,
the riser card or system
board is faulty. See
“Getting Help” in the
Hardware Owner’s
Manual.

E1914

DRAC5 Conn2

Cbl

DRAC 5 cable is missing
or disconnected.

Reconnect the cable. See
“Installing a RAC Card”
in the

Hardware Owner’s

Manual.

E1B01

USB#

Overcurrent

Device plugged in the
specified USB port caused
an overcurrent condition.

Reseat the device cable.
If the problem persists,
replace or remove the
device.

E2110

MBE DIMM # & #

One of the two indicated
DIMMs has had a memory
multi-bit error (MBE).

See “Troubleshooting
System Memory” in
the

Hardware Owner’s

Manual.

Table 1-2.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions