Crown Boiler CWD138 User Manual

Page 20

Advertising
background image

18

18

TABLE 4: PERMISSIBLE VENT SYSTEMS AND PRINCIPLE VENT COMPONENTS

MANUFACTURER

VENT SYSTEM

SIZE

CONDENSATE

TRAP

WALL

THIMBLES

HORIZONTAL

TERMINATION

VERTICAL

TERMINATION

HEAT FAB

SAF-T VENT

EZ SEAL

3

9321

(NOTE 3)

7393GC

7393GCS

5391CI

ELBOW: 7314TERM
TEE: 7390TEE

5300CI

4

9421

(NOTE 3)

7493GC

7493GCS

5491CI

ELBOW: 7414TERM
TEE: 7490TEE

5400CI

SAF-T VENT SC

3

SC03DRN

(NOTE 3)

SC03FS

SC03FSA

ELBOW (NOTE 5):
SC03HT + 7314TERM
TEE (NOTE 5):
SC03HT + 7390TEE

5300CI + SC03VT

(NOTE 6)

4

SC04DRN

(NOTE 3)

SC04FS

SC04FSA

ELBOW (NOTE 5):
SC04HT + 7414TERM
TEE (NOTE 5):
SC04HT + 7490TEE

5400CI

+ SC04VT

(NOTE 6)

PROTECH

SYSTEMS

INC.

FASNSEAL

3

FSHDT3

FSWT3

ELBOW: FSELB9003 + FSBS3
TEE: FSTT3

FSRC3

4

FSHDT4

OR FSCD4

(NOTE 4)

FSWT4

ELBOW: FSELB9004 + FSBS4
TEE: FSTT4

FSRC4

FASNSEAL W2

3

W2-T3

+W2-DF3

W2-WT3

ELBOW: FSA-SWDW3
+ FSELB9003 + FSBS3
TEE: FSA-SWDW3 + FSTT3

W2-RC3

4

W2-T4

+ W2-DF4

W2-WT4

ELBOW: FSA-DWSW4
+ FSELB9004 + FSBS4
TEE: FSA-SWDW4 + FSTT4

W2-RC4

Z-FLEX

SVE

SERIES III

(“Z-VENT III”)

3

SVEDWCF03

2SVSWTEF03

ELBOW: 2SVSTEX0390
TEE: 2SVSTTF03

2SVSRCF03

4

SVEDWCF04

2SVSWTEF04

ELBOW:
2SVEEWCF0490 + 2SVSTPF
TEE: 2SVSTTF04

2SVSRCF04

METAL-FAB

CORR/GUARD

3

CGSWDS(3”)

CGSWWPK(3”)

ELBOW: CGSW90LTM(3”)
TEE: CGSWTTM(3”)

CGSWC(3”)

4

CGSWDS(4”)

CGSWWPK(4”)

ELBOW: CGSW90LTM(4”)
TEE: CGSWTTM(4”)

CGSWC(4”)

NOTES:

1) See vent system manufacturer’s literature for other part numbers that are required such as straight pipe, elbows, fi restops and
vent supports.
2) In addition to terminals shown, Crown coaxial terminals may be used in some cases. See Table 3 for applications and Crown
part numbers.
3) All Heat Fab condensate traps shown may be installed in vertical or horizontal run.
4) Protech FSCD4 condensate trap may be installed in a vertical or horizontal run. All other Protech traps must be installed in a
horizontal run only.
5) Heat Fab Saf-T Vent SC may not be used for horizontal coaxial venting - a separate air inlet pipe must be provided for hori-
zontal direct vent systems. SC03HT or SC04HT adapters are used to adapt from SC pipe to terminal. Use of SC pipe in horizon-
tal systems does allow for reduced clearances to combustibles in some applications. See Table 2.
6) Heat Fab SC03VT or SC04VT adapters are required on any vertical vent system using Saf-T Vent SC even when combustion
air is obtained through a separate pipe or from the boiler room.

7) Metal-Fab CGSWDS condensate traps may only be installed in a horizontal run.