Crown Boiler CWD138 User Manual

Page 65

Advertising
background image

63

63

Pilot

light?

24 volts

between 24V

and

24V (GND) on

ign. module?

See "Intermittent
Ignition System
Troubleshooting
Chart" on page 64.

Minimum

pressure at

switch called in

Table 7 present

across switch?

* Blockage in venting system
* Vent system not installed in
accordance with installation manual
* Excessive silicone on I.D. of vent
system joints
* Blockage, condensate or leakage in
vacuum switch tubing
* Improperly sealed flue collector
* Damaged or missing fan gasket
* Defective fan
* Wind at horizontal vent terminal in
excess of 40 mph

Main

burners

light?

N

Do burner,

circulator and

fan shut down at

end of call for

heat?

END

Y

Does boiler shut

down when t'stat

wire is removed from

terminal R on

R8285?

* T'stat or zone system
calling for heat
* T'stat wires shorted

* Internal boiler wiring
problem, consult
Crown representative

Y

N

N

Y

Do burners shut

down before

gauge temp

exceeds high limit

setting +15F?

* Defective L4080D
* Sensing bulb not bottomed
out in well

N

Y

N

Y

N

Y

*Tubes reversed on
pressure switch
*Leak in tubes at pressure
switch connection
*Loose pressure switch
harness connection

Y

N

TROUBLESHOOTING CHART FOR BOILERS WITH R8285 CONTROL SYSTEM - PAGE 2 OF 2