10

Getting Started With Your System

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see

dell.com/environmental_datasheets.

Temperature

Operating

10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1 ºF/550 ft.

Storage

–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour

Relative humidity

Operating

20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 G at 5 Hz to 350 Hz for 15 min

Storage

1.54 G at 10 Hz to 250 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse on
each side of the system) of 31 G for 2.6 ms in the
operational orientation

Storage

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms

Altitude

Operating

–16 m to 3048 m (–50 ft to 10,000 ft)

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1 ºF/550 ft.

Storage

–16m to 10,600 m (–50 ft to 35,000 ft)

Airborne Contaminant Level

Class

G1 as defined by ISA-S71.04-1985