4. Repeat Step 3 for additional client subnets.

For example:
networking subnets edit 10.10.76.0 255.255.252.0 -PrivateIPs

10.10.78.121,10.10.78.122,10.10.78.123,10.10.78.124 -PublicIPs

10.10.78.125,10.10.78.126

5. (iSCSI only) Configure additional IP addresses for the iSCSI SAN subnets.

hardware fabrics iscsi edit <name> -ControllersIPs <x.x.x.x>

For example:
hardware fabrics iscsi edit SANb -ControllersIPs

192.11.18.14,192.11.18.15,192.11.18.16,192.11.18.17

hardware fabrics iscsi edit SAN -ControllersIps

192.11.18.10,192.11.18.11,192.11.18.12,192.11.18.13

6. Add the NAS appliance.

hardware nas-appliances add-appliance <ApplianceServiceTag>

For example:
hardware nas-appliances add-appliance L846185

7. For iSCSI, the IQNs will have FluidFS NasControllerX in the name.
8. In the output of the following command, make sure Luns Accessibility shows Optimal from all NAS

controllers to all NAS volumes.
hardware storage-subsystem view

9. Perform an incremental format and join the new NAS appliance to the FluidFS cluster.

hardware nas-appliances join-appliance <ApplianceID>

For example:
hardware nas-appliances join-appliance 2

10. After the previous command completes, confirm that the NAS appliance Status is Optimal in the

output of the following command.
hardware nas-appliances status-list