Dell LATITUDE D400 User Manual

Page 17

Advertising
background image

remove the hard drive

, and boot the computer from a bootable floppy disk or CD. Then turn off the computer,

reinstall the hard drive, and restart the computer. Run the Hard-Disk Drive tests as described in "

Using the Dell

Diagnostics

."

Hard-disk drive controller failure 0 —

The hard drive does not respond to commands from the computer.

Turn off the computer,

remove the hard drive

, and boot the computer from a bootable floppy disk or CD. Then

turn off the computer, reinstall the hard drive, and restart the computer. If the problem persists, try another

drive. Run the Hard-Disk Drive tests as described in "

Using the Dell Diagnostics

."

Hard-disk drive failure —

The hard drive does not respond to commands from the computer. Turn off the

computer,

remove the hard drive

, and boot the computer from a bootable floppy disk or CD. Then turn off the

computer, reinstall the hard drive, and restart the computer. If the problem persists, try another drive. Run the

Hard-Disk Drive tests as described in "

Using the Dell Diagnostics

."

Hard-disk drive read failure —

The hard drive may be defective. Turn off the computer,

remove the hard

drive

, and boot the computer from a bootable floppy disk or CD. Then turn off the computer, reinstall the hard

drive, and restart the computer. If the problem persists, try another drive. Run the Hard-Disk Drive tests as

described in "

Using the Dell Diagnostics

."

Insert bootable media —

The operating system is trying to boot to a nonbootable floppy disk or CD. Insert a

bootable floppy disk or CD.

Invalid configuration information-please run System Setup Program —

The system configuration

information does not match the hardware configuration. The message is most likely to occur after a memory

module is installed. Correct the appropriate options in the system setup program. See "

Using the System Setup

Program

."

Keyboard clock line failure —

For external keyboards, check the cable connection. Run the Keyboard

Controller test as described in "

Using the Dell Diagnostics

."

Keyboard controller failure —

For external keyboards, check the cable connection. Restart the computer,

and avoid touching the keyboard or the mouse during the boot routine. Run the Keyboard Controller test as

described in "

Using the Dell Diagnostics

."

Keyboard data line failure —

For external keyboards, check the cable connection. Run the Keyboard

Controller test as described in "

Using the Dell Diagnostics

."

Keyboard stuck key failure —

For external keyboards or keypads, check the cable connection. Restart the

computer, and avoid touching the keyboard or keys during the boot routine. Run the Stuck Key test as

described in "

Using the Dell Diagnostics

."

Memory address line failure at address, read value expecting value —

A memory module may be faulty

or improperly seated.

Reinstall the memory modules

and, if necessary, replace them.

Memory allocation error —

The software you are attempting to run is conflicting with the operating system,

another program, or a utility. Turn off the computer, wait 30 seconds, and then restart it. Try to run the

program again. If the error message still appears, see the software documentation.

Memory data line failure at address, read value expecting value —

A memory module may be faulty or

improperly seated.

Reinstall the memory modules

and, if necessary, replace them.

Memory double word logic failure at address, read value expecting value —

A memory module may be

faulty or improperly seated.

Reinstall the memory modules

and, if necessary, replace them.

Memory odd/even logic failure at address, read value expecting value —

A memory module may be

faulty or improperly seated.

Reinstall the memory modules

and, if necessary, replace them.

Memory write/read failure at address, read value expecting value —

A memory module may be faulty

or improperly seated.

Reinstall the memory modules

and, if necessary, replace them.