Diagnostic port (d_port) – Dell POWEREDGE M1000E User Manual

Page 119

Advertising
background image

Fabric OS Troubleshooting and Diagnostics Guide

103

53-1002751-01

Diagnostic Port (D_Port)

10

Example

The following example shows the results of a portdporttest - -show output where the electrical and
optical tests pass but the link test fails.

switch:admin> portdporttest --show 10/39

D-Port Information:

===================

Slot:

10

Port:

39

Remote WWNN:

10:00:00:05:33:7e:69:c4

Remote port:

24

Mode:

Manual

No. of test frames:

12 Million

Test frame size:

1024 Bytes

Payload Pattern:

JTSPAT

FEC (enabled/option/active):

Yes/No/No

CR (enabled/option/active): No/No/No

Start time:

Mon Jan 16 05:57:51 2012

End time:

Mon Jan 16 05:58:56 2012

Status:

FAILED

================================================================================

Test

Start time

Result

EST(HH:MM:SS)

Comments

================================================================================

Electrical loopback05:57:52 PASSED

--------

----------

Optical loopback 05:58:06 PASSED

---------

---------

Link traffic test 05:58:13 FAILED

--------

See failure report

================================================================================

Roundtrip link latency:

934 nano-seconds

Estimated cable distance:

1 meters

Buffers required:

1 (for 1024 byte frames at 16Gbps speed)

Failure report:

Errors detected (local):

CRC, Bad_EOF, Enc_out

Errors detected (remote):

CRC, Bad_EOF

Please use portstatsshow and porterrshow for more details on the above errors.

Example

Use the portDportTest - -show all command to display the capabilities and test results of all the
D_Ports in a switch.

switch:admin> portdporttest --show all

Port State SFP Capabilities Test Result

=============================================

24 ONLINE E,O PASS

26 ONLINE E,O RESPONDER

33 OFFLINE --- RESPONDER