Device login issues – Dell POWEREDGE M1000E User Manual

Page 50

Advertising
background image

34

Fabric OS Troubleshooting and Diagnostics Guide

53-1002751-01

Device login issues

3

In some cases, you may find that the port has been locked as an L_Port and the device
attached is a fabric point-to-point device such as a host or switch. This would be an incorrect
configuration for the device and therefore the device cannot log into the switch.

To correct this type of problem, remove the Lock L_Port configuration using the portCfgDefault
command.

switch:admin> portcfgshow

Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--

Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN

Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

where AN:AutoNegotiate, ..:OFF, ??:INVALID,

SN:Software controlled AutoNegotiation.

4. Enter the portErrShow command; then, check for errors that can cause login problems. A

steadily increasing number of errors can indicate a problem. Track errors by sampling the port
errors every five or ten minutes until you see the problem occur again.

5. Enter the portFlagsShow command; then, check to see how a port has logged in and where a

login failed (if a failure occurred):

switch:admin> portflagsshow

Port SNMP Physical Flags

-------------------------------

0 Offline In_Sync PRESENT U_PORT LED

1 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE

LOGIN NOELP LED ACCEPT

2 Offline No_Light PRESENT U_PORT LED

3 Offline No_Module PRESENT U_PORT LED

4 Offline No_Module PRESENT U_PORT LED

5 Offline No_Light PRESENT U_PORT LED

6 Offline No_Module PRESENT U_PORT LED

7 Offline No_Module PRESENT U_PORT LED

8 Offline No_Light PRESENT U_PORT LED

9 Offline No_Light PRESENT U_PORT LED

10 Offline No_Module PRESENT U_PORT LED

11 Offline No_Module PRESENT U_PORT LED

12 Offline No_Module PRESENT U_PORT LED

13 Offline No_Module PRESENT U_PORT LED

14 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE

LOGIN NOELP LED ACCEPT

15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED LOGIN

LED

6. Enter the portLogDumpPort portid command where the port ID is the port number; then, view

the device-to-switch communication.

switch:admin> portlogdumpport 8 | more

time task event port cmd args