Logical switch issues – Dell POWEREDGE M1000E User Manual

Page 84

Advertising
background image

68

Fabric OS Troubleshooting and Diagnostics Guide

53-1002751-01

Logical switch issues

7

Logical switch issues

CAUTION

When a logical switch is created, all configuration for the logical switch is set to factory defaults.
When a logical switch is deleted, all configuration for the logical switch is deleted permanently
and is not recoverable.

Symptom

The indicated slot is empty.

Probable cause and recommended action

You used the lsCfg command and an empty slot was specified.

Reissue the command with the appropriate slot number.

Symptom

Validation of switch configuration changes is not supported on this platform.

Probable cause and recommended action

This platform is unknown to the logical switch subsystem.

Symptom

Given slot number is not valid on this platform.

Probable cause and recommended action

You are specifying a slot number that is not valid on the platform, for example, slot 0 on a Brocade
DCX or slot 12 on a Brocade DCX-4S.

Symptom

Slot must be enabled to configure ports.

Probable cause and recommended action

You may only attempt to configure ports on enabled blades (blades may be faulted).

Symptom

Unable to determine slot type.

Probable cause and recommended action

The slot type is not known to the logical switch. Verify the slot and try again.

Symptom

There are no ports on this slot.

Probable cause and recommended action

There are no configurable ports on the slot indicated by the lsCfg command. Verify the ports and try
again.

Symptom

Unable to remove ports from their current switch.

Probable cause and recommended action

When moving ports to a switch, you must first remove them from the switch in which they reside.
This error message is displayed if this step fails.

Advertising