Fabric OS Troubleshooting and Diagnostics Guide

33

53-1002751-01

Device login issues

3

Device login issues

A correct login is when the port type matches the device type that is plugged in. In the following
example, it shows that the device connected to Port 1 is a fabric point-to-point device and it is
correctly logged in an F_Port.

switch:admin> switchshow

switchName:brcd5300

switchType:64.3

switchState:Online

switchMode:Native

switchRole:Subordinate

switchDomain:1

switchId:fffc01

switchWwn:10:00:00:05:1e:40:ff:c4

zoning:OFF

switchBeacon:OFF

FC Router:OFF

FC Router BB Fabric ID:1

Area Port Media Speed State Proto

=====================================

0 0 -- N8 No_Module

1 1 --

N4 Online FC F-Port 10:00:00:05:1e:8f:c1:31

2 2 -- N8 No_Module

3 3 -- N8 No_Module

(output truncated)

61 61 -- N8 No_Module

62 62 -- N8 No_Module

63 63 -- N8 No_Module

64 64 id N2 Online

E-Port 10:00:00:05:1e:34:d0:05 "1_d1"

(Trunk master)

65 65 -- N8 No_Module

66 66 -- N8 No_Module

67 67 id AN No_Sync

68 68 id N2 Online

L-Port 13 public

69 69 -- N8 No_Module

70 70 -- N8 No_Module

71 71 id N2 Online

L-Port 13 public

72 72 -- N8 No_Module

73 73 -- N8 No_Module

74 74 -- N8 No_Module

75 75 -- N8 No_Module

76 76 id N2 Online

E-Port 10:00:00:05:1e:34:d0:05 "1_d1"

(upstream)(Trunk master)

77 77 id N4 Online

F-Port 10:00:00:06:2b:0f:6c:1f

78 78 -- N8 No_Module

79 79 id N2 Online E-Port 10:00:00:05:1e:34:d0:05 "1_d1"

(Trunk master)

Pinpointing problems with device logins

1. Log in to the switch as admin.

2. Enter the switchShow command; then, check for state logins.

3. Enter the portCfgShow command to see if the port is configured correctly.