Configuration planning, Entering the bios configuration utility – Dell Adaptec U320 SCSI Raid 0 or 1 Controller Card User Manual

Page 15

Advertising
background image

NOTICE: It is recommended that you not use the unused portion of the global hot spare as it may result in a
single drive RAID 1.

Drive Roaming

Drive roaming enables a RAID volume to be moved from one controller to another controller without interruption.
Each drive has a unique ID which can be physically changed by setting a jumper to allow drive roaming.

Formatting

Most drives can re-assign sectors to recover from failures.

Formatting a drive may allow re-assigning of failed sectors, allowing a RAID controller to utilize the drive. See
"

Verifying or Formatting a Disk

" for more information.

Rebuilding

The Rebuild feature of the Adaptec U320 SCSI RAID 0 or 1 allows for an array to synchronize the hard drives, and
restore fault tolerance in a redundant RAID array. See "

Rebuilding Arrays

" for more information.

Configuration Planning

Optimal configurations are different for each unique purpose. When planning your RAID configuration, factors to
consider are:

Number of hard drives
Purpose of the Array

Fault Tolerance
Performance
Capacity

Spare Drives

Global Hot Spares

Entering the BIOS Configuration Utility

During POST of the system a splash screen will appear:

Advertising