Removing and inserting physical disks, Md3000 maintenance considerations – Dell PowerVault MD3000 User Manual

Page 114

Advertising
background image

114

Hardware Considerations

2 After attaching the SAS cables, wait at least three minutes for the EMM to

reach optimal state.

NOTE:

You may experience a transitional failure on multiple EMMs in the MEL log

while the system updates.

Removing and Inserting Physical Disks

Refer to the following guidelines to ensure that physical disks are safely

removed from and inserted into the MD3000/MD3000i RAID storage array.

• Wait at least 60 seconds between removing a drive and inserting a

replacement.

• When pulling a drive from a storage array to move it to a different slot,

wait 60 seconds before inserting the drive into the new slot.

• Wait at least 60 seconds between the removal of drives from a storage

array.

• Wait at least 60 seconds between the insertion of drives into a storage

array.

In a large configuration, storage management software may take up to

10 seconds to detect hardware changes.

MD3000 Maintenance Considerations

For Linux kernels, stop and then restart the SMagent after performing one of

the following maintenance tasks:

• Move a controller offline or replace a controller.
• Remove SAS cables from or attach SAS cables to host servers running Red

Hat

®

Enterprise Linux

®

(version 4), SUSE

®

Linux Enterprise Server 9, or

SUSE Linux Enterprise Server 10 operating systems.

NOTE:

If a Resolve Topology Conflicts message appears in the Status portlet of the

Summary page after restarting the SMagent, it may be necessary to restart the host

server to clear this message. Do not select the Resolve selection in the Topology

Conflict wizard. The MD3000 will continue to service I/O requests, but the array

could become partially managed if only in-band management is used. Stop all I/O

operations on any host servers that were involved in the maintenance operation

and restart the system.

Advertising